EM8622 Wireless Control Panel
| ENGLISH EM8622 - Wireless Control Panel Table of contents 1.0 Introduction ........................................................................................................... 3 1.1 Packing contents ............................................................................................... 3 1.2 Control panel front ............................................................................................. 3 1.3 Control panel inside ..........................................................
| ENGLISH 1.0 Introduction Congratulations with the purchase of this high-quality Eminent product! This product has undergone extensive testing by Eminent’s technical experts. Should you experience any problems with this product, you are covered by a five-year Eminent warranty. Please keep this manual and the receipt in a safe place. Register your product now on www.eminent-online.com and receive product updates! 1.
| ENGLISH 1.3 Control panel inside Battery contact, please check positive and negative terminals Battery compartment Tamper switch Wired cable connection Red wire = + 12V Black wire = - GND Low battery notification : the keypad beeps twice every two seconds and the LED indicator flashes once. 2.0 Installation Install the batteries and mount the control panel on the door frame or the wall before use.
| ENGLISH 1) Remove the screw and open the case 2) Install the batteries according to the positive and negative signs (Remove the insulating strip before the first use) 3) Mount the backcover on the door frame or wall 4) Close the case and replace the screw Note : Opening the cover will trigger the tamper switch ! You can disarm it by entering the admin code 123456 followed by [#]. Note : The default admin code is : 123456. See chapter “Change Admin Code” to change it.
| ENGLISH Note : When an entry delay is set, the external control panel will NOT warn you with an audio signal when a sensor is triggered. Only the alarm system itself will give an audio signal ! 3.2 Disarm the alarm system Users can disarm the alarm system by using the control panel or by using RFID tags. 3.2.1 Using control panel to disarm Input user code or admin code, and press the [Disarm] key.
| ENGLISH 3.2.2 Using RFID Tag to disarm If direct disarm by RFID tag is disabled (this is the default power saving mode when using batteries), user needs to press [*] to wake up the control panel and then put RFID tag close to the reader to disarm the alarm system.. When the power saving function is disabled, user can put the RFID tag directly close to the control panel to disarm the alarm system. 3.2.
| ENGLISH 3.2.4 Emergency Call When the control panel is in SOS Speed Dial mode, user just holds the [SOS] key for 3 seconds, the LED indicator flashes once, the control panel beeps once, and the alarm system alarms immediately. When the control panel is not in SOS Speed Dial mode, user needs to input user code or admin code before holding the [SOS] key for 3 seconds to send an alarm. 3.2.
| ENGLISH 4.0 Connect to the alarm system Note : The default admin code is : 123456. See chapter “Change Admin Code” to change it. Note : The default user code is : 1234. See chapter “Change User Code” to change it. Make sure the alarm system is in connection state (press code on alarm system and press the memo button). Input the admin code on the control panel and press the Arm, Disarm or Home mode button. When the control panel is connected successful the alarm system will give one beep. 5.
| ENGLISH 3. Put the RFID tag close to the RFID reader. If one beep is heard the connecting is successful. When 2 beeps are heard, the RFID tag was already connected to the control panel. To remove all connected RFID tags, input the admin code followed by the # button. Press and hold down the 9 button for six seconds. All RFID tags are cleared after one beep is heard. Note : you can connect up to 50 RFID tags to the EM8622.
| ENGLISH 6.0 Settings Before changing the settings of the control panel, the control panel should be in “setup-state”. 6.1 Enter Setup-state Note : The default admin code is : 123456 Input the admin code followed by the [#] button to wake up the control panel. Press [3] to enter the setup-state. The LED indicator will be on. Note : When there is no key press within 10 seconds the control panel will exit the setup-state automatically. You can also press [#] to exit the setup-state. 6.
| ENGLISH After setting a delay time, press the [Arm] button on the control panel. The control panel will send the Arm command to the alarm system after the delay time you set in the control panel. Note : This setting will not apply to the Home mode. If both the control panel and the alarm system have a delay time set, the actual delay time is the total of both times ! Enter the setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds the setup is succesful.
| ENGLISH 6.3.1 Disable SOS code Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 6.3.2 Enable SOS code Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Note : Default setting is 0, SOS code is disabled.
| ENGLISH 6.4 Keyboard tone Keyboard tones can be switched on or off. If they are switched off, the beep when a setup is successful will also be switched off ! 6.4.1 Disable keyboard tone Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 6.4.2 Enable keyboard tone Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful.
| ENGLISH 6.5 Disarm system by RFID tag Users can enable or disable the function of disarming the alarm system by RFID tag, or disarming silent by RFID tag. 6.5.1 Disable disarming by RFID tag Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 6.5.2 Enable disarming by RFID tag Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful.
| ENGLISH 6.5.3 Disarming silently by RFID tag The alarm panel and siren will hoot twice when disarming the alarm system by RFID tag. If set disarming silently by RFID tag, the alarm system and siren will keep silent when disarming. Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. Note : Default setting is 1, turn on disarming by RFID tag and the siren will hoot when disarming. 6.
| ENGLISH 6.6.1 Enable power savig mode Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 6.6.2 Disable power saving mode If the control panel is powered by an external 12V power supply (not included), it is recommended to switch of the power saving mode. Users can disarm the alarm system directly by RFID tag.
| ENGLISH 6.7 Change user code A user can use its own code to wake up the control panel and send Arm, Disarm or Home mode commands to the alarm system. The control panel can only have one user code. Note : The default user code is 1234. Please change this code at first use ! Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 6.
| ENGLISH 6.9 Reset the control panel After a reset the user code, admin code and all other settings will be restored to default. Only the connected RFID tags will remain working. To remove the connected RFID tags, please refer to chapter “Connect RFID Tag to control panel”. Enter Setup-state and input : When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful. 7.
| ENGLISH 8.0 Service and support This user’s manual has been carefully written by Eminent’s technical experts. If you have problems installing or using the product, please fill out the support form at the website www.eminent-online.com/support. You can also contact us by phone. Please check www.eminent-online.com/support for the helpdesk phone number and opening hours. 9.
| ENGLISH 10.0 Warranty conditions The five-year Eminent warranty applies to all Eminent products, unless mentioned otherwise before or during the moment of purchase. After buying a second-hand Eminent product the remaining period of warranty is measured from the moment of purchase by the product’s initial owner. Eminent warranty applies to all Eminent products and parts, indissolubly connected or mounted to the product it concerns.
NL EN FR ES PT IT DE HU PL | | | | | | | | | CE COMPLIANCE VERKLARING VAN OVEREENSTEMMING CE COMPLIANCE DECLARATION OF CONFORMITY CONFORMITÉ CE DÉCLARATION DE CONFORMITÉ CUMPLIMIENTO NORMATIVO CE DECLARACIÓN DE CONFORMIDAD CONFORMIDADE CE DECLARAÇÃO DE CONFORMIDADE CONFORMITÀ CE DICHIARAZIONE DI CONFORMITÀ CE-BEREINSTIMMUNG ÜBEREINSTIMMUNGSERKLÄRUNG CE MEGFELELÉS MEGFELELŐSÉGI NYILATKOZAT DEKLARACJA ZGODNOŚCI CE Toepassing van Richtlijnen van de Raad| Application of Council Directives | Application des d