Data Sheet
Accuracy: ±0.25%of full scale
Cold Junction Compensation: Automatically ± 0.1°C/1°C
Line Compensation: Maximum 10 Ohm
Sensor Break Protection: Upscale
Sampling Cycle: 0.1 second
On/Off Temperature
Controller
3 Digits Process (PV) and 4 Digits Set (SV) display
Process input ( TC, RTD )
ON-OFF control form
Selectable heating and cooling function
Selectable temperature offset value
Operation type selection with hysteresis
Minimum pulling time adjustment
for control outputs
Password protection for programming mode
Saving and Recovery of user parameters
TC (J,K,R,S,T Input Types) and
RTD inputs selectable by parameter
Low Power Consumption, Energy
saving and Environmentally Friendly with 2VA
Return to Factory Settings
Supply Voltage
230Vac, 115Vac
10-30Vdc
Output (C)
2R
1R
or
C
0 0
4
B
48x48x80,52 mm
Output-1
Power Supply
Dimensions
A
B
4
1R
2R
C
1xRelay Output (NO+C) 5A@250Vac
2xRelay Output (NO+C) 5A@250Vac
10-30Vdc (-%15, +%10)
115Vac (-%15, +%10) 50/60Hz
230Vac (-%15, +%10) 50/60Hz
5
6
3
5A@250Vac
2 x 5A@250Vac
Temperature Controllers
ECO LITE
ECO-LITE
X1
ECO-LITE
OUT
PUT
X2
PT-100
TC
Inputs
C
NO
C
NO NO
Specifications
Technical Specification