Instructions

1.2 Ordering Information
All order information of ESM-1510
Temperature Controller are given on the
table at left. User may form appropriate
device configuration from information and
codes that at the table and convert it to the
ordering codes.
Firstly, supply voltage then other
specifications must be determined. Please
fill the order code blanks according to your
needs.
Please contact us, if your needs are
out of the standards.
V Symbol means Vac,
Z Symbol means Vdc,
Symbol means Vac/dcW
c
6
1.3 Warranty
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts from
the delivery date. This warranty is in force if duty and responsibilities which are determined in
warranty document and instruction manual performs by the customer completely.
1.4 Maintenance
Repairs should only be performed by trained and specialized personnel. Cut power to the device
before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl
alcohol or water to clean the external plastic case.
A BC D E FG HI /
/
U
V W Z/
/
0 00 2 0 0
1
Relay Output ( resistive load 5 A@250 V V , 1 NO + 1NC )
Output-1
E
Supply VoltageA
Input Type
BC
Scale(°C)
ESM-1510
24 V V ( ± 15% ) 50/60 Hz
3
115 V V ( ± 15% ) 50/60 Hz
4
230 V V ( ± 15% ) 50/60 Hz
5
10...30 V Z
8
9
Customer
2
SSR Driver Output (Maximum 28 mA,15 V Z)
00
12
05
09
J, Fe CuNi IEC584.1(ITS90)
PTC (Note-1)
-50°C
150°C
0°C
800°C
-19.9°C
99.9°C
PT 100, IEC751(ITS90)
10
K, NiCr Ni IEC584.1(ITS90)
-50°C
400°C
0°C
999°C
11
PT 100, IEC751(ITS90)
14
-50°C
400°C
PT 1000, IEC751(ITS90)
13
-19.9°C
99.9°C
PT 1000, IEC751(ITS90)
15
PTC (Note-1)
-19.9°C
99.9°C
Temp. Sensor which is given with ESM 1510
V
0
None
1
PTC-M6L40.K1.5 (PTC Air Probe with 1.5 m silicon cable)
2
PTCS-M6L30.K1.5.1/8” (PTC Liquid Probe with 1.5 m silicon
cable)
Customer
3
NTC-M5L20.K1.5 (NTC Probe, thermoplastic moulded with
1.5 m cable for cooling application)
4
NTC-M6L50.K1.5 (NTC Probe, stainless steel housing with
1.5 m cable for cooling application)
9
Note-1 : If input type is selected PTC or NTC (BC = 12, 15, 18, 19 ),
Temperature sensor is given with the device. For this reason,
If input type is selected as PTC, sensor type (V = 0,1 or 2) or
If input type is selected as NTC, sensor type (V = 0,3 or 4) must be
declared in ordering information.
19
-19.9°C 99.9°C
-50°C 100°C
18
NTC (Note-1)
NTC (Note-1)
24 V W ( - 15%, + 10% ) 50/60 Hz
2