User manual
6.ChangingandSavingTemperatureSetValue
MainOperationScreen
WhenSET buttonpressed‘’S’’ ledwill
beactiveandtemperaturesetvaluewill
bedisplayed.
SETValueScreen
Temperaturesetvaluecan
bechangedwithincrement
anddecrementbuttons.
WhenENTER buttonpressed
temperaturesetvaluecanbesaved.
‘’S’’ willbeinactiveandgoesbackto
mainoperationscreen.
MainOperationScreen
Temperaturesetvalueparameter(Default=50)MODBUS ADDRESS:40001
Temperaturesetvalue,canbeprogrammedbetweenminimumtemperaturesetvalueand
maximumtemperaturesetvalue.
O
F
O
C
P
S
O
F
O
C
PS
4.2DeviceLabelandConnectionDiagram
4.ElectricalWiringDiagram
4.1SupplyVoltageInputConnectionoftheDevice
Note-1 : External fuse is recommended.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse that on power supply inputs must be on
phase connection.
External fuse that on power supply inputs must be on (+)
connection.
V
Z
c
230VV CONNECTION DIAGRAM
5.FrontPanelDefinitionand AccessingtotheMenus
BUTTON DEFINITIONS
LED DEFINITIONS
1. Increment Button :
2. Decrement, Silencing Buzzer and Downloading to Prokey Button :
3. Set Button :
4. Enter Button :
7.Celcius led :
8.Fahrenheit led :
9.Set led :
10.Program led :
** It is used to increase the value in the Set screen and Programming mode.
** It is used to decrease the value in the Set screen and Programming mode.
** It is used to silence the buzzer.
** If Prc =0, it is used to download from device to prokey.
** In the main operation screen; if this button pressed, set value will be displayed. Value can be
changed using increment and decrement buttons. When Enter button pressed, value is saved
and returns back to main operating screen.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
** It is used to saving value in the Set screen and programming screen.
** Indicates that device is in C mode.
** Indicates that device is in F mode.
** Indicates that device is in Set value changing mode.
**Blinks in programming mode .
o
o
5. Cooling led :
6.Heatingled:
** Thisledindicatesthatcoolingcontrolisselectedandprocessoutputrelayisactive.Ifany
ofcompressorprotectiontimeactive,thisledblinks.
Thisledindicatesthatheatingcontrolisselectedandprocessoutputrelayisactive.**
O
F
O
C
P
S
5 6 7 7
9
10
1
2
3
4
8
Cooling
Heating
SensorOffsetParameter(Default=0)MODBUS ADDRESS:40007
from-20to20°CforNTC(-50°C,100°C)orPTC(-50°C,150°C)orJ Type TC(0°C,800°C)
orJ Type TC(0°C,1000°C)orPT-100(-50°C,400°C)orPT-1000(-50°C,150°C)or
PT-100(-20°C,100°C),
from -36 to 36 °F for NTC(-58°F, 212°F) or PTC(-58°F, 302°F) or J Type TC (32°F,1472°F) or
or K Type TC (32°F,1830°F) or PT-100(-58°F, 752°F) or PT-1000(-58°F, 752°F) or
PT-100(-4°F, 212°F),
from -10.0 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC(-50.0°C,150.0°C) or
PT-100 (-19.9°C,99.9°C),
from -18.0 to 18.0°F for NTC(-58.0°F,212.0°F) or PTC(-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
Compressor Start Delay at Power On Parameter ( Default = 0)
MODBUS ADDRESS:40009
When power is first applied to the device, compressor is on when this time delay is expired.
It can be adjusted from 0 to 20 minutes.
Compressor Stop-Start Delay Parameter ( Default = 0) MODBUS ADRES:40010
When compressor is inactive, this time delay must be expired for activation of the
compressor. It can be adjusted from 0 to 20 minutes.
Compressor Start-Start Delay Parameter ( Default = 0) MODBUS ADRES:40011
This time delay must be expired between two activation of the compressor. It can be
adjusted from 0 to 20 minutes.
MODBUS ADDRESS:30001TemperatureValue
MODBUS ADDRESS:30002LedStatus:0.bit CLed,
6.bitCompressorLed,
13.bitProgramLed,14.bitSetLed
MODBUS ADDRESS:30003DeviceStatus:
1.bitBuzzerStatus
2.bitSensorLostStatus
MODBUS ADDRESS:30004OutputStatus
MODBUS ADDRESS:30005DeviceTypeandDeviceVersion
o
A
A
A
A
A
6.2 Modbus Adresses of Device Status Parameters (Read Input Register)
Operating Type Parameter ( Default = 0) MODBUS ADDRESS:40008
If parameter value is ‘0’ device skips to parameter
5 6 9 10
121187
1.Switchoffthedevice.
2.PutinPROKEY thenenergizethedevice.
3.Whenthedeviceisenergized,theparametervaluesinPROKEY,startdownloadingtothedevice
automatically. Atfirst,messageisshownonthedisplay,whenloadinghasfinished,
messageisshown.
4.After10secondsdevicestartstooperatewithnewparametervalues.
5.RemovethePROKEY.
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
c
2.3PanelMounting
2.4RemovingfromthePanel
3.UsingProkey
DOWNLOADINGFROMDEVICETOPROKEY
1.Thedeviceisprogrammedbyusingtheparameters.
2.EnergizethedevicethenputinPROKEY andpressbutton.Messageisshownonthe
display.Whentheloadinghasfinished,messageisshown.
3.Pressanybuttontoturnbacktomainoperationscreen.
4.RemovethePROKEY.
DOWNLOADINGFROMPROKEY TODEVICE
NOTE:messageisshownwhenanerroroccurswhileprogramming.Ifyouwanttoreload,put
inPROKEY andpressbutton.Ifyouwanttoquit,removePROKEY andpressbutton. The
devicewillturnbacktomainoperationscreen.
NOTE:messageisshownwhenanerroroccurswhileprogramming.Ifyouwanttoreload,
switchoffthedeviceandputinPROKEY thenenergizethedevice.Ifyouwanttoquitremove
PROKEY andpressbutton. Thedevicewillturnbacktomainoperationscreen.
TOUSEPROKEY,VALUEOFTHEPrCPARAMETERMUSTBE‘0’.
IFPrC=1 ANDBUTTONISPRESSEDMESSAGEWILL BESHOWN.10s.LATER
DEVICETURNSBACKTOTHEMAINOPERATIONSCREENOR YOUCANPRESSSET
BUTTONTOTURNBACKTOMAINOPERATIONSCREEN.
6.1ProgrammingModeParameterList
Hysteresis Parameter for Compressor Output ( Default = 1 )
MODBUS ADDRESS:40004
from 1 to 20°C for NTC (-50°C, 100°C) or PTC (-50°C, 150°C) or J Type TC ( 0°C, 800°C ) or
K TypeTC ( 0°C, 1000°C or PT-100 Type ( -50°C,400°C ) or PT-1000Type ( -50°C,400°C )
or PT-100Type ( -20°C,100°C ),
from 1 to 36°F for NTC (-58°F, 212°F) or PTC (-58°F, 302°F) or J Type TC (32°F,1472°F)or
K Type TC (32°F,1830°F) or PT-100 Type (-58°F,752°F) or PT-1000 Type (-58°F,752°F)
or PT-100Type (-4°F,212°F)
from 0.1 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC (-50.0°C,150.0°C)
or PT-100 (-19.9°C,99.9°C),
from 0.1 to 18.0°F for NTC (-58.0°F,212.0°F) or PTC (-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude around
set value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is formed
below or around set value and this zone is
named hysteresis.
ON
OFF
Temperature
Control
Output
Set
HSt
Time
HSt
Time
Minimum Temperature Set Value Parameter (Default = Minimum Value of Device
Scale ) MODBUS ADDRESS:40005
Temperature set value can not be lower than this value.
This parameter value can be adjusted from minimum value of device scale to maximum
temperature set value parameter
Maximum Temperature Set Value Parameter (Default = Maximum Value of Device
Scale ) MODBUS ADDRESS:40006
Temperature set value can not be bigger than this value.
This parameter value can be adjusted from minimum temperature set value parameter
to maximum value of the device scale
Decimal Seperator Enabling Parameter ( Default = 0 ) MODBUS ADDRESS:40003
Disable.
Enable.
Temperature Unit Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40002
°C selected.
°F selected.
SensorDefectParameter(Default=0)MODBUS ADRES:40012
Compressorisactiveduringthistimeperiodincaseofprobedefect(Default=0)
MODBUS ADRES:40013
If probe defect parameter is 2, then this parameter is observed. It can be adjusted
from 0 to 99 minutes.
Compressor is OFF in case of sensor defect.
Compressor is ON in case of sensor defect.
Compressor operates periodically according to and Time periods in
case of sensor defect.
Compressorisinactiveduringthistimeperiodincaseofprobedefect
(Default=0)MODBUS ADRES:40014
If probe defect parameter is 2, then this parameter is observed. It can be adjusted
from 0 to 99 minutes.
Buzzer Function Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40015
Buzzer is inactive.
Buzzer is active during sensor failures.
Buzzerisactiveduringthistime
Whenthisparameteris1,ifdecrementbuttonispressed,isobserved.Inthis
conditionbuzzerisactivetillbuzzersilencebuttonispressed.
(Default=)MODBUS ADDRESS:40016
Ifbuzzerfunctionselectionparametervalue=0,thisparametercannotbe
observed.Buzzerstaysactiveduringthistime.Itcanbeadjustedfrom1to99minutes
Programming Section Accessing Password
.
( Default = 0 ) MODBUS ADDRESS:40019
It is used for accessing to the programming section. It can be adjusted from 0 to 9999. If it is
selected 0, password will not be asked
PROKEY communication selected.
Communication Mode Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40017
Rs485 communication selected.
Slave ID Parameter ( Default = 1 ) MODBUS ADDRESS=40018
Device communication address parameter (1 to 247).
O
F
O
C
PS
O
F
O
C
PS
PowerSupplyConnection
c
a
EXTERNAL
FUSE
(1A T)
Note-1
Supply
Switch
Supply Voltage
4
5
L
N
2
1
6
Note: If sensor input type is selected J, K, PT-100 or PT-1000 (BC =05,10,11 or 14) parameter is
skipped.
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz,
24V ( %15) 50/60Hz ,
24V ( %15) 50/60Hz ,
Z
V
V
V
W
±
±
±
±
10..30 V - 1.5 W
Mustbedeterminedinorder.
Screen Blinking
Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter is 1, internal buzzer starts to operate.
WhenSET buttonispressedfor5
seconds,“P”ledstartstoblink.If
programmingmodeentering
passwordisdifferentfrom0,
programmingmodeenteringscreen
willbeobserved.
MainOperationScreen
ProgrammingScreen
Changethevaluewithincrement
anddecrementbuttons.
HysteresisValuefor
CompressorOutput
Press SET button for accessing to the parameter
value. Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter.
PressOKbuttonforsavingthe
parameter.
Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter
PasswordEnteringScreen
ProgrammingMode
EnteringScreen
PressOKbuttonfor
accessingtothe
passwordentering
screen.
PasswordEnteringScreen
Enterprogrammingmodeaccessingpassword
withincrementanddecrementbuttons.
Note2: If programming mode accessing password is 0, only three parameters
are accessible, and the parameter values can be changed.
PressOKbuttonforentering
thepassword.
Note1: Ifprogramming
modeaccessing
passwordis0,
TemperatureUnitscreen
isobservedinsteadof
programmingscreen
HysteresisValuefor
CompressorOutput
If no operation is performed in programming mode for 20 seconds, device turns to main
operation screen automatically..
i
HysteresisParameter
forCompressor
6.5EnteringToTheProgrammingMode,ChangingandSavingParameter
O
F
O
C
S
P
O
F
O
C
S
P
O
F
O
C
S
P
O
F
O
C
S
P
6.4FailureMessagesinESM-3710-NTemperatureController
6.3OperationGraphicsofESM-3710-N ControllerTemperature
O
F
O
C
S P
O
F
O
C
S P
O
F
O
C
PS
O
F
O
C
S
P
1-IfOperatingTypeParameterValue=1(Cooling),
SwitchOnDelay AfterPowerOnParameterValue 1,
CompressorStop/StartTimeDelayParameterValue 1and
CompressorStart/StartTimeDelayParameterValue 1;
³
³
³
Power
Time
Hst
SET
Time
Output
Time
Time
Output
Led
°C
ON
OFF
Temperature
Value
TemperatureControlOutput
SET
HSt
Time
HSt HSt
Time
2-IfOperatingTypeParameterValue=0(Heating),
i
In ON/OFF control algorithm, temperature value is tried to keep equal
to set value by opening or closing the last control element. ON/OFF controlled system,
temperature value oscillates continuously. Temperature value’s oscillation period or
amplitude around set value changes according to controlled system. For reducing
oscillation period of temperature value, a threshold zone is formed below or around
set value and this zone is named hysteresis. Action of control output is described with
figures above.
, , , , and Parameters are observed if Operation type
is selected “Cooling”. If operation type is selected “Heating ” ,skip to the parameter.
i
RelayorSSROutput
21 4 5 6 7
P/N: ESM-3710-N
L
N
a
SupplyVoltageInput
TemperatureSensor Input
TC,NTC,PTC,PT-100
orPT-1000
230V ( %15) 50/60Hz
115V ( %15) 50/60Hz
24V ( %15) 50/60Hz
Z
V
V
V
±
±
±
10...30 V
Must be determined in order.
ü
ESM3710-N
SET
P
3
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
üü
ESM3710-N
SET
P
üü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
1
2
3
3
3
PROKEY
RS-485
or
6
7
a
16(8)A
@250V 1HPV
L
N
2
4 5
1
NTC
L
N
16A Fuse
3
NCNO
C
OUTPUT
INPUTSCALE
(-50 ,100 ;°C °C °F °F-58 ,212 )
NTC
16(8)A @
250V 1HPV
230 V ±15%
50/60Hz-1.5VA
V
P/N:ESM-3710-N-5.18.0.1/00.00/2.3.0.0
PROKEY
RS-485
or
7
OUTPUT
NO NCC
LINE
LOAD
LOAD
(+)
(-)
ForSSROutput
(+)
(-)