Instructions

6. Changing and Saving Temperature Set Value
Main Operation Screen
When SET button pressed ‘’S’’ led will
be active and temperature set value will
be displayed.
SET Value Screen
Temperature set value can
be changed with increment
and decrement buttons.
When ENTER button pressed
temperature set value can be saved.
‘’S’’ will be inactive and goes back to
main operation screen.
Main Operation Screen
Temperature set value parameter (Default=50) MODBUS ADDRESS:40001
Temperature set value, can be programmed between minimum temperature set value and
maximum temperature set value .
O
F
O
C
P
S
O
F
O
C
P
S
8
6.1 Programming Mode Parameter List
Decimal Seperator Enabling Parameter ( Default = 0 ) MODBUS ADDRESS:40003
Disable.
Enable.
Temperature Unit Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40002
°C selected.
°F selected.
O
F
O
C
P
S
O
F
O
C
P
S
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ü
ESM3710-N
SET
P
ü
ü
ESM3710-N
SET
P
3. Set Button :
** In the main operation screen; if this button pressed, set value will be displayed. Value can be
changed using increment and decrement buttons. When Enter button pressed, value is saved
and returns back to main operating screen.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
4. Enter Button :
** It is used to saving value in the Set screen and programming screen.
LED DEFINITIONS
7.Celcius led :
o
** Indicates that device is in C mode.
8.Fahrenheit led :
o
** Indicates that device is in F mode.
9.Set led :
** Indicates that device is in Set value changing mode.
10.Program led :
**Blinks in programming mode .
5. Cooling led :
** This led indicates that cooling control is selected and process output relay is active. If any
of compressor protection time active, this led blinks.
6.Heating led :
** This led indicates that heating control is selected and process output relay is active.