Data Sheet
2003 Sep 15 8
Philips Semiconductors Product specification
Silicon temperature sensors KTY83 series
Fig.6 Deviation of sensor resistance as a function
of operating current in still liquid.
T
amb
=25°C.
handbook, halfpage
2
20
10
0
−10
01
MGG707
I
cont
(mA)
∆R
(Ω)
APPLICATION INFORMATION
SYMBOL PARAMETER CONDITIONS TYP. UNIT
∆R
25
drift of sensor resistance at 25 °C 10000 hours continuous operation;
T
amb
= 175 °C
1 Ω