Datasheet
:
:
:
Max. operating temperature
Sensor type
Protection tube material
(TCIR) Bayonet Valve Type with Fittingnut
TCIR-M06-L050.1.K
Technical drawing
-50 °C / +200 °C
DIN/IEC-584 ‘‘K’’ NiCr-Ni
AISI304 (DIN1.4301)
Thermoresistances
Temperature Sensors
www.emkoelektronik.com.tr
AEMKO
:
:
Diameter (M)
Immersion Length (L)
6 mm
50 mm
www.emkoelektronik.com.tr
7mm
48mm
27mm
20mm
47mm
ø13
mm
Diameter (M)
mm
Immersion
Length (L)
TCIR M- L-0 6 0 5 0 .1.K
White
Black
NiCr
Ni
+
_
Thermoelement Connections