Appendix A - Serial Remote Control (RS232)
Serial Remote Control (RS232)
e XDS1 V2 is equipped with a 9-pin RS232 port for system remote control via a serial
cable (not provided by EMM Labs). Please use a standard RS232 cable. Do not use a null
model cable, as this will not work. RS232 communication port settings:
• 19,200 baud
• 8 bits
• 1 stop bit
• no ow control
• no parity bit
Commands to the XDS1 V2
All commands sent to the XDS1 V2 consist of 3 ASCII characters (all lowercase) followed by
a carraige return or <CR>. Repeating a <CR> will repeat the last command sent. Received
commands are not stored in a stack. ey need to be sent in intervals of at least 50ms to
allow enough time for the XDS1 V2 to execute a command before receiving the next one.
Command Function
ply Start Playback
pse Pause Playback
stp Stop Playback
mod Toggles through the SACD playback layers. Only works when not playing.
rpt Toggles through the dierent repeat modes
nxt Jumps ahead a track
prv Jumps back a track
© 2013 EMM Labs Inc., All Rights Reserved. EMM Labs reserves the right to amend specifications & design without notice.