XPR-1 XPR-1 Mono-block Reference Power Amplifier User Manual
Important Safety Precautions and Explanation of Symbols ! The exclamation point within an equilateral triangle is intended to alert the user to the presence of important installation, operation, and service instructions in this manual. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltages within the enclosure that may be of sufficient magnitude to constitute a risk of electric shock to the user.
Protect power supply cables from being pinched, walked on, or otherwise damaged. Be especially careful where the power cable enters the power outlet and the unit. Only connect the XPR-1 an electrical outlet or extension cord of appropriate type and rating. MOST power strips and extension cords are NOT sufficient to safely supply the power required by the XPR-1. Using a power source of insufficient capacity will constitute a safety risk and also seriously compromise the performance of the XPR-1.
XPR-1 XPR-1 Mono-block Reference Power Amplifier Contents Important Safety Precautions and Explanation of Symbols Introduction..........................................................................................3 About This Manual...............................................................................4 Features..............................................................................................5 Unpacking..................................................................................
XPR-1 Page 2
XPR-1 Introduction The XPR-1 Reference Mono-block Power Amplifier embodies everything we’ve learned about designing audiophile amplifiers in one stunning package: virtually unlimited raw power, the absolute best in sound quality, the latest technology, and elegant good looks. For the dedicated audiophile, nothing competes with a true monoblock design - full isolation for each channel with no compromises and no distractions. For the truly discerning music lover, nothing competes with the XPR-1.
XPR-1 About This Manual This User Manual will provide you with all the information you need to get started enjoying your XPR-1 Reference Mono-block Power Amplifier. We suggest that you read through the entire manual; we kept things as short and direct as possible. Even if you’re an expert user, you will probably find some interesting information and useful suggestions.
XPR-1 Features The XPR-1 Reference Mono-block Power Amplifier is a truly exceptional performer. It combines the power, reliability, and superb sound quality of a great audiophile amplifier with the features and aesthetics of a true audio showpiece. Some of the features offered by the XPR-1 include: • • • • • • • • • • • • • Fully balanced; fully differential - for the ultimate in audio purity and performance.
XPR-1 Unpacking Your XPR-1 was carefully packed and should reach you in perfect condition. If you notice any shipping damage or other issues when you unpack it, please contact Emotiva immediately. Gently remove your XPR-1 from the packing carton and remove all wrappings and shipping material. It is important to save the boxes and all packing materials in case your power amp ever needs to be moved or shipped back to the factory for service. We truly value customer feedback and would like to hear from you.
XPR-1 XPR-1 Front Panel 1 2 STANDBY 3 PEAK DIM METER ORIENTATION 4 5 6 7 1. Accent Lighting Blue accent lighting is provided by cool, long lived LEDs. 2. Channel Status and Meter LEDs The display has a single Channel Status LED (the bottom one), and a blue LED Bargraph Meter above it. Either or both are active depending on the configuration chosen. If a fault occurs, the LED above the Standby button, the Channel Status LED, and the LED Bargraph Meter LEDs will flash red. 3.
XPR-1 5. Dim Button Controls the brightness of the Accent Lighting and all LEDs (in four steps). 6. Meter Button Press to switch between LED and Accent Lighting modes: 1) LED Bargraph Meters + Status LEDs + Accent Lighting. 2) Status LEDs only. 3) All lights and LEDs off. 4) Status LEDs only. 5) Status LEDs + Accent Lighting only. Pressing the Meter button while at configuration 5) will return you to configuration 1). 7.
XPR-1 XPR-1 Rear Panel 1 2 3 4 5 TRIGGER UN-BAL INPUT 5-12 VDC OUTPUT 12VDC BAL + -- 115V 230V 6 7 8 1. Speaker Terminals Super heavy duty, audiophile-grade, gold plated, and clear acrylic five-way binding posts accept the heaviest speaker cables and lugs as well as standard banana plugs and bare wire. 2.
XPR-1 5. Balanced (XLR) Input Standard XLR connector accepts a line level balanced input. 6. AC Power Switch Switches the main AC power to the XPR-1 On and Off. When this switch is off, no controls operate (the XPR-1 cannot be turned On from the front panel). 7. IEC Power Cord Receptacle Accepts a standard IEC C19/C20 AC power cable and requires a dedicated 20 Amp high-current AC outlet. If you do not have an appropriate outlet, please contact your electrician to install one.
XPR-1 Quick Start To get the most from your XPR-1, we urge you to read the entire manual. If you just can’t wait to listen to it, this section will cover the basics you need to get started. • • • • • • Find a secure location for your XPR-1s. Make sure you choose a stand or shelf that can support the full weight of the XPR-1s safely. Connect each XPR-1 to your signal source. Connect each XPR-1 to an 8 ohm or 4 ohm speaker using heavy gauge speaker wires (at least 12 gauge).
XPR-1 Connections ! A word about safety The XPR-1 is capable of delivering large voltages and currents at its speaker terminals. If, while music is playing, the speaker terminals or speaker cables are inadvertently shorted to each other, to interconnect cables, or to ground, the XPR-1 can cause damage to associated equipment, and may even pose a risk of electric shock. • • • • Ensure that the XPR-1 is powered Off before changing any connections.
XPR-1 Connecting an input source to your XPR-1 Your XPR-1 amplifier has separate balanced (XLR) and unbalanced (RCA) inputs; a switch selects which input is active. Be sure to set this switch correctly. We suggest using reasonably high quality cables, keeping cables no longer than necessary, and avoiding running signal cables near power cables and speaker cables whenever possible. DO NOT connect a digital signal to the input of your XPR-1 (or you may damage it or your speakers).
XPR-1 Configuration and Operation Line Voltage The XPR-1 can operate from line voltages of 115 VAC +/- 10% or 230 VAC +/- 10%, and will automatically detect and switch between them. The Input Voltage LEDs on the rear panel indicate which voltage range has been detected. AC Power Switch (rear panel) The rear-panel AC Power switch controls the main AC power for your XPR-1. When this switch is in the Off position, the amplifier will not operate. Turning it On will put the XPR-1 into Standby mode.
XPR-1 Care and Maintenance Periodic Maintenance The XPR-1 power amplifier requires no periodic maintenance or calibration. Cleaning the XPR-1 • • • If necessary, the XPR-1 should be cleaned gently with a soft rag. If something sticky gets on the front panel or case of the XPR-1, it should be cleaned with a mild cleaning solution applied to a soft rag, followed by wiping with a clean rag dampened with plain water and drying with a soft dry rag or cloth.
XPR-1 Specifications Topology: Cross-coupled balanced dual-differential input, with a fully discrete, fully balanced, high current, short signal path Class A/B Differential Reference power amplifier section and Optimized Class-H™ power supply topology. Number of Channels: 1 Power Output (rated power; THD < 0.1%): 1000 watts (1.0 kW) into 8 ohms. 1750 watts (1.75 kW) into 4 ohms. Rated Power Bandwidth (at rated power; 8 Ohm load): 20 Hz to 20 kHz + / -0.1 dB.
XPR-1 Power Supply: 2.5 kVA toroidal power transformer. 240,000 uF of total storage capacitance. Input Sensitivity (for rated power; 8 Ohm load): 3.5 V Gain: 29 dB. Input Connections: RCA; unbalanced (audiophile quality, machined, solid brass, gold plated). XLR; balanced. Input Impedance: 100k ohms (unbalanced). 51k ohms (balanced). Trigger: Trigger Input: 5 - 20 V (AC or DC); <10 mA input current required. Trigger Output: 12 VDC; can drive any load up to 50 mA.
XPR-1 Troubleshooting The XPR-1 is carefully designed and manufactured from high-quality precision components to ensure years of trouble free operation. We really doubt you’ll ever have any problems with your XPR-1 but, if you do, here are a few things you could try: Problem: No sound is heard (nothing is lit). Reason: You have no AC power. • • • Verify that the rear panel AC Power switch is On. Verify that your circuit is live. Verify that the line cord on the XPR-1 is fully inserted and is tight.
XPR-1 Problem: No sound is heard (all the LEDs are flashing red). Reason: The XPR-1 is in Protect mode, which indicates a Fault condition. • • • Switch the AC Power switch Off and On to clear the Fault condition. If the fault remains, look for a shorted speaker cable or damaged speaker. Check your sources and source connections (a bad interconnect, DC on the input, or an otherwise bad source component can cause a fault). Problem: The Standby LED is red and the XPR-1 fails to come on when triggered.
XPR-1 Emotiva Audio Corporation Five-Year Limited Warranty What does this warranty cover? Emotiva Audio Corporation (“Emotiva”) warrants its products against defects in materials and workmanship. How long does this coverage last? This warranty commences on the date of retail purchase by the original retail purchaser and runs for a period of five years thereafter. This warranty is transferrable to any person that owns the warranted product during the Term.
XPR-1 EMOTIVA SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM OR RELATED TO ANY DEFECTS IN OR DAMAGES TO ITS PRODUCTS. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. How do you get service? In order to make a claim under the warranty, you must: 1. Call a customer service representative (“CSR”) of Emotiva at (1-877-EMO-TECH / 1-877-366-8324).
XPR-1 Accessories Speaker cables Using high-quality speaker cables and audio interconnects will ensure that you get the best sound quality and maximum reliability from your XPR-1s and the speakers connected to them. Emotiva Audio offers high-quality speaker cables and audio interconnects that feature solid engineering, premium build quality, excellent performance, and reasonable cost (you will find them in the Interconnects section of our website at www.emotiva.com).
XPR-1 Notes All information contained in this manual is accurate to the best of our knowledge at the time of publication. In keeping with our policy of ongoing product improvement, we reserve the right to make changes to the design and features of our products without prior notice. User Manual Revision 1.