Power Supply:
2.5 kVA toroidal power transformer.
240,000 uF of storage capacitance.
Input Sensitivity (for rated power; 8 Ohm load):
2.6 V
Gain:
29 dB
Input Connections:
RCA; unbalanced (audiophile quality, machined, solid brass, gold plated); one per channel.
XLR; balanced; one per channel.
Input Impedance:
100k ohms (unbalanced).
51k ohms (balanced).
Trigger:
Trigger Input: 5 - 20 V (AC or DC); <10 mA input current required.
Trigger Output: 12 VDC; can drive any load up to 50 mA.
Power Requirements:
115 VAC or 230 VAC +/- 10% @ 50 / 60 Hz (auto-switching).
Protection:
The XPR-2 is protected against excessive operating temperature, shorted speaker
connections, ground faults, and other common fault conditions. If a fault occurs on one or
more channels of the XPR-2, the LED above the Standby button, the Channel Status LEDs,
and the LED Bargraph Meter LEDs associated with the channel that is reporting the fault
will ash red. Returning the XPR-2 to Standby or switching off the AC Power will reset the
protection circuitry.
Dimensions:
17” wide x 9.5” high 19.5” deep (includes feet and binding posts);
requires additional 4” of depth clearance to accommodate the power cord.
Weight:
100 lbs (net); 114 lbs (boxed).