User's Manual
Table Of Contents
- Glossary
 - Product Description
 - Regulatory and Compliance
- EmbracePlus product labeling
 - EmbracePlus laboratory testing
 - EmbracePlus Symbols used in labeling
 - Intended use
 - Indication for use statement
 - Intended population and use environment
 - Patients population and Medical Conditions
 - Essential Performance Statement and Safety Information
 - Service Life
 - Limitations
 - Warnings and Precautions
 - Risks and Benefits
 - EmbracePlus Materials & Biocompatibility
 - Technical Specifications and Performance Characteristics
 - Storage and Use Conditions
 - Dust and Water Resistance
 - Compatibility with MR and X-ray Scanning
 - EMC Environment
 
 - Getting started with EmbracePlus
 - Troubleshooting
 - Privacy
 
The information contained in this document is confidential and is the property solely of Empatica, S.r.l.. Any reproduction in part or in whole without 
the written permission of Empatica, S.r.l. is prohibited. © Empatica S.R.L, 2021. All rights reserved. 
23 
Compatibility with MR and X-ray Scanning 
You must not wear EmbracePlus during either an MRI or an X-ray scan. 
During an X-ray, the doctor will usually ask you to remove all metal objects since they can affect the 
quality of the scan. For an MRI, it is especially important to remove all metal objects because the MRI’s 
magnets will attract them. 
EMC Environment 
Guidance and Manufacturer's declaration - electromagnetic emissions 
EmbracePlus is intended for use in the electromagnetic environment specified below. The user of the 
EmbracePlus should assure that it is used in such an environment.  
Emission Test 
Compliance 
Electromagnetic environment 
RF emission 
CISPR 11 
Group 1 
EmbracePlus uses RF energy only for its internal function. 
Therefore its RF emissions are very low and are not likely to 
cause any interference in nearby electronic equipment.  
RF emission 
CISPR 11 
Class B 
The  EmbracePlus  device  is  suitable  for  use  in  domestic 
establishments and in establishments directly connected to 
the  low  voltage  power  supply  network  that  supplies 
buildings used for domestic purposes.  
Harmonic Emission 
EN 61000-3-2 
Not Applicable 
Voltage Fluctuation/ 
flicker emission 
EN 61000-3-3 
Not Applicable 
FCC Compliance 
The FCC id of the EmbracePlus is: 
The EmbracePlus device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: 
1.  This device may not cause harmful interference, and 
2.  This  device  must  accept  any  interference  received,  including  interference  that  may  cause 
undesired operation (FCC Title 47, Subpart A, Part 15.19(3)). 
Changes or modifications not expressly approved by the party responsible for compliance could void the 
user’s authority to operate the equipment (FCC Title 47, Subpart A, Part 15.21)  