The appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Always check for the validity of the pressure regulator. Technical specification of the pressure
regulator:
i. Refer to TECHNICAL DATA in this manual.
ii. Max. consumption: 2.5kg/h.
iii. Should be certified according to ANSI Z21.1 / CSA 1.1 and comply with local code.
This appliance must be installed and serviced by a competent person
This appliance shall be installed in accordance with the regulations in force and only used in a well
ventilated space.
Remove all packaging before using the gas cooktop
Ensure that the gas and complies with the type stated on the rating label
Do not attempt to modify the gas cooktop in any way
Caution: This appliance is for cooking purposed only. It must not be used for other purposes, for example
room heating.
For your Safety
This gas cooktop is designed to be operated by adults. Do not allow children to play near or with the
gas cooktop.
The gas cooktop gets hot when it is in use.
Children should be kept away until it has cooled.
Children can also injure themselves by pulling pans or pots off the gas cooktop.
CAUTION: This appliance is for cooking purposes only. It must not be used for other purposes, for
example, room heating.
When Use
This gas cooktop is intended for domestic cooking only. It is not designed for commercial or industrial
purposes.
When in use a gas cooking appliance will produce heat and moisture in the room in which it has been
installed. Ensure there is a continuous air supply, keeping air vents in good condition or installing a
cooker hood with a venting hose.
When using the gas cooktop for a long period of time, the ventilation should be improved, by opening
a window or increasing the extractor speed.
Do not use gas cooktop if it is in contact with water. Do not operate the gas cooktop with wet hands.
Ensure the control knobs are in the closed position when not in use.
In the event of the burner flames being accidentally extinguished, turn off the burner control and do
not attempt to re-ignite the burner for at least 1 min.