Use and Care Manual

Instructions for Converting Range to Operate on Liquefied Petroleum Gas
1. Convert the Pressure Regulator
To access the gas regulator, pull the
range away from the cabinet wall.
The gas regulator is located at the
bottom right corner of the range.
a. Electrical shock hazard can occur
and result in injury or death.
Disconnect electrical power to the
range before servicing. Do not
remove regulator or allow it to
tur
n during servicing.
b. Un
screw the cap from the regulator.
Do not remove the spring from
the regulator.
c. Unscrew the insert from the cap and
turn it over so the longer stem is
facing the cap. Replace insert on the
cap. Replace the cap on the
regulator.
2. Convert Top Burner for LP/ Propane Gas
Save the natural gas orifices
removed from the appliance for possible future
conversions to natural gas. You
should use the
following process to c
onvert to Natural gas.
Take extra care when handling steel parts.
a. Remove cooking grates, burner caps
and inner burner rings.
b. Lift off outer burner heads and burner
bases.
c. Remove the factory installed natural gas
orifices from the center of the orifice
holders using a 7mm nut driver.
Remember to keep the original natural
gas orifices for future c
onversions back
to natural gas. Replace the LP orifice in
each ori
fice holder. Tighten each orifice
until snug. Use caution not to over
tighten.
Position for LPPosition for NG
Care should be taken when removing and replacing gas components. Use proper
support to prevent damage to components.
29