Use and Care Manual

25
A(in) B(in) C(in) D E
29.92 1.97 mini 0.79 mini Air intake Air exit 0.20in
Before you install the cooktop, make sure that
The work surface is square and level, and no structural members interfere with
space requirements.
The work surface is made of a heat-resistant material.
If the cooktop is installed above an oven, the oven has a built-in cooling fan.
The installation will comply with all clearance requirements and applicable
standards and regulations.
A suitable isolating switch providing full disconnection from the mains power
supply is incorporated in the permanent wiring, mounted and positioned to comply
with the local wiring rules and regulations.
The isolating switch must be of an approved type and provide a 0.12in air gap
contact separation in all poles (or in all active [phase] conductors if the local wiring
rules allow for this variation of the requirements).
The isolating switch will be easily accessible to the customer with the cooktop
installed.
You consult local building authorities and by-laws if in doubt regarding installation.
You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall
surfaces surrounding the cooktop.
When you have installed the cooktop, make sure that
The power supply cable is not accessible through cupboard doors or drawers.
There is adequate flow of air from outside the cabinetry to the base of the cooktop.
If the cooktop is installed above a drawer or cupboard space, a thermal protection
barrier is installed below the base of the cooktop.
The isolating switch is easily accessible by the customer.
Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not apply
force onto the controls protruding from the cooktop.
Locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do not
apply force onto the controls protruding from the cooktop.
Fix the cooktop on the work surface by screw four brackets on the bottom of
cooktop (see picture) after installation.
Adjust the bracket position to suit for different work surface’s thickness.