PIN-HOLE
FREESTANDING TUB
INSTALLATION INSTRUCTIONS
WARNING: Risk of electric shock. Do not permit electrical appliances near any
bathtub when bathtub contains water.
WARNING: Risk of electric shock. Connect only to a circuit protected by a Ground-
Fault Circuit-Interrupter (GFCI).
WARNING: Risk of injury or property damage. Please read all instructions thoroughly
before beginning installation, including the following requirements.
WARNING: Risk of electric shock. A qualified electrician should make all electrical
connections.
Product information
Each bath arrives ready for installation. Factory installed components include a blower
motor with power supply cord, check valve, air piping and switch. Other than electrical
wiring and plumbing, no assembly is needed.
WARING: Unauthorized modification may cause unsafe operation or affect
performance of the bath with pinhole. Do not relocate the blower motor, or make
other modifications to the system in the absence of Kit instructions, as this could
adversely affect the performance and safe operation of the bath with pinhole. Empava
shall not be liable under its warranty or otherwise for personal injury or damage cased
by any such unauthorized modification.
Electrical Requirements
The installation must have a Class A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device
(RCD). The GFCI or RCD protect against line-to-ground shock hazard. Use a 110 V, 60Hz dedicated
service for the bath.
Product Notices
NOTICE: Keep the area around the blower clean and free of debris. Ensure that the area
around the blower is free of sawdust, insulation, dirt and other small loose debris. Such material
can block the blower air ducts and reduce the air flow through the blower.
1. Prepare the Site
NOTICE: Measure your actual product for site preparation.
NOTICE: Provide generous, unrestricted access to the blower. Make sure the bathtub
bottom at least 1/2” above floor. You must provide access for servicing the blower. The
access must be located immediately next to the blower.
NOTICE: Do not lift the bath by the piping or blower, our use the piping or blower for structural
support of the bath. To avoid damage to the bath, lift by the rim at the sides of the bath.