Owner`s manual
32925-3-0115 Page 23
B. BEFORE LIGHTING
WHAT TO DO IF YOU SMELL GAS
C. Use only your hand to push in or turn the gas control
1. Openbottomlouverassembly(ifapplicable).
2. SetREMOTE/OFF/ONswitchto"OFF."
3. Turnoffallelectricpowertotheapplianceifserviceistobe
performed(ifapplicable).
4. Pushingascontrolknobslightlyandturnclockwise
to"OFF."Donotforce.
5. Closebottomlouverassembly(ifapplicable).
1. STOP!Readthesafetyinformationlabel.
2. Open bottom louver assembly (if
applicable).
3. Set REMOTE/OFF/ON switch to
"OFF."
4. Turn off all electric power to the ap-
pliance(ifapplicable).
5. Pushingascontrolknobslightlyand
turnclockwise
to"OFF."
NOTE:Knobcannotbeturnedfrom"PILOT"to"OFF"un-
lessknobispushedinslightly.Donotforce.
6. Wait ten (10) minutes to clear out any gas. Then smell for
gas,includingneartheoor.Ifyousmellgas,STOP!Follow
"B"inthesafetyinformationabove.
If you do not smell gas, go to the
next step.
7. Findpilot-Followmetaltubefrom
gas control. The pilot is in front of
theburnerontherightside.
8. Turn gas control knob counter-
clockwise to"PILOT."
9. Push in control knob all the way
and hold in. Repeatedly push the
Piezo Ignitor Button until the pilot is lit. Continue to hold the
controlknobinforaboutone(1)minuteafterthepilotislit.
Releaseknob,anditwillpopbackup.Pilotshouldremain
lit. If it goes out, repeat steps 5 through 9.
• Ifknob does not popup when released, STOP and
IMMEDIATELY call a qualied service technician or
gas supplier.
• Ifthepilotwillnotstaylitafterseveraltries,turnthegas
controlknobto"OFF"andcallyourservicetechnician
or gas supplier.
10. Turn gas control knob counterclockwise
to
"ON."
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turnonallelectricpowertotheappliance(ifapplicable).
13. Closebottomlouverassembly(ifapplicable).
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING: