Owner`s manual

32925-3-0115Page 26
Labelallwirespriortodisconnectionwhenservicingcontrols.Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivoltthermopileisselfpowered,gasvalvedoesnotrequire110
volts. Maximum length of 20 feet of 16 AWG to conductor wires is
tobeusedwithalloptionalswitches.

Millivoltsystemandallindividualcomponentsmaybecheckedwith
a millivolt meter 0-1000 MV range. The thermopile reading needs
tobebetween325and400millivolts.

Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention:The remote receiver bracket is not used in this
installation.
1. Theremotereceivercannotbeplacedbesidethegasvalve
andburnerassembly.
2. Whenfacingtheappliance,theremotereceivermustbeplaced
to the left of the gas valve.
Refer to remote control installation and operating instructions for
more details on remote control.
Figure 41
H N
REMOTE CONTROL
RECEIVER/
THERMOSTAT/CONTROLE E
DISTANCE DU RECEPTEUR
GAS VALVE
VALVE DE GAZ
(OPTIONAL) REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR (FACULATIVE)
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150 C
WIRE OR ITS EQUIVALENT.
o
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150 C DU L’EQUIVALENT.
o
WIRING DIAGRAM
REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
GAS VALVE
THERMOCOUPLE
(NATURAL)
THERMOCOUPLE
(LPG)
PILOT
VEILLEUSE
THERMOPILE
PRESSURE TAP
MILLIVOLT WIRING