PROFLAME - IP CONTROL SYSTEM
RECEIVER
TheProameReceiver connects directly
to the gas valve and stepper motor with a wiring harness. The
Receiverispoweredby4AAtypebatteries.TheReceiveraccepts
commandsviaradiofrequencyfromtheTransmittertooperatethe
applianceinaccordancewiththeparticularProamesystemcon-
guration.TheReceiverthreepositionsliderswitchcanbesetto
one of three positions: ON (Manual Override), Remote (Remote
control) or Off.
3 Positions Slider
PRG Key

14 PINterminal

OPERATING PROCEDURE

Install the 4AA batteries into the receiver battery bay. Note the
polarityofbatteryandinsertintothebatterybayasindicatedon
the Battery cover (+/-). Place the 3 position slider switch in the
“Remote” position.
Usingtheendofapaperclip,orothersimilarobject,inserttheend
ofthepaperclipintotheholemarked“PRG”ontheReceiverfront
cover.TheReceiverwill“beep”three(3)timestoindicatethatit
is ready to synchronize with a Transmitter. Install the 3 AAA type
batteriesintheTransmitterbatterybay,locatedonthebaseofthe
Transmitter.WiththebatteriesalreadyinstalledintheTransmitter,
pushtheOnbutton.TheReceiverwill“beep”fourtimestoindicate
theTransmitter’scommandisacceptedandsetstotheparticular
code of that Transmitter. The system is now initialized.

With the system in the “OFF” position, press the Thermostat But-
tonandtheModeButtonatthesametime.LookattheLCDscreen
ontheTransmittertoverifythataCorFisvisibletotherightofthe
Room Temperature display. (Figures 49 and 50)
Figure 49 - Fahrenheit
Figure 50 - Celsius