Owner`s manual
32925-3-0115Page 36
IP OPERATING INSTRUCTIONS
5.25 VDC ELECTRONIC CONTROL VALVE
Theelectroniccontrolvalvesystemincludestheabilitytoswitch
the pilot from a standing pilot mode to an intermittent pilot mode.
• IP Mode - In the Intermittent Pilot mode, when the unit is
turnedON,itwillcausesparktothepilot,lightthepilot,
thenallowtheburnertolight.Whentheunitisturnedto
OFF,boththeburnerandpilotwillbeOFF.
• CPI Mode - In the Continuous Pilot mode, the pilot re-
mainsONcontinuouslyevenwhentheburneristurned
OFF.
Note:Asmalltoggleswitchislocatedonabracketthatisusedto
switch from IP (upward position) to the CPI (downward position).
See Figure 61.
When the unit is turned to ON, the electrical current will energize
asparktothepilotigniter.Oncethepilotsensorheatsup(aftera
fewseconds),thevalvewillbeenergized,allowinggastoowto
theburner.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for In-
termittent Pilot controls foundin this manual, and on labels
found in the control compartment located in the lower cavity
of the appliance.
2. During the operating season (or in power outage periods), it is
recommended that the pilot remain in the CPI (standing pilot
mode) to reduce cold start issues, and/or conserve battery
backuppowerduringapoweroutage.
3. The gas valve has inlet and outlet pressure taps as shown in
Figure 61.Refertopage12forgaspressurerequirements.
DFC
ELECTRONIC
CONTROL
MODULE
REMOTE
CONTROL
RECEIVER
AA (4)
BATTERY
BACKUP
IPI
CPI
PILOT SELECTOR SWITCH
IPI - INTERMITANT PILOT (UP)
CPI - CONTINUOUS PILOT (DOWN)
SPARK ROD
GROUND
9 PIN CONNECTOR
PILOT
SENSOR
STEPPER
MOTOR
REGULATOR
GAS VALVE
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
IGNITOR
SENSOR
PILOT
ASSEMBLY
Figure 61