Owner`s manual

32084-6-0214Page 34
Optional Controls
WARNING
Potential risk of re, electric shock, and personal injury.
Take precautions to reduce such risks.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
External controls are available for use with the UltraSaver. See
page 15. Connections for these controls are provided for easy
installation. See Figure 53.
The terminal connection #1 is for use only with Empire’s FRBTPL
Wireless thermostatic remote.
The two red wire connections #2 and #3 are for use with low
voltage (millivolt) controls systems or an On/Off switch. Install
the controls according to the instructions for low voltage systems
provided with the controls.
CAUTION
DO NOT use 24V or 120V controls with the millivolt connec-
tions as damage will occur.
Figure 53
WARNING
BEFORE OPERATING THIS APPLIANCE, CAREFULLY
READ THE FOLLOWING.
1. Verify the gas line service does not exceed the maximum and
minimum pressures. See Page 22.
2. Check and inspect the appliance for gas leaks. In the event of
gas leaks, turn off the gas supply to the wall furnace immedi-
ately and call your gas supplier. Verify the gas line has been
purged.
3. Verify that all exhaust and inlet air pipes are unobstructed and
properly joined.
4. Visually verify the burner is free of dust and debris.
5. Verify that all panels are secured in place and that the casing
front has been locked in position.
6. Verify that the polarity of the connections are correct and the
line voltage power leads are secure.
7. After verifying and checking all the above points, proceed to
lighting instructions. Refer to Page 32.
Notice: Verify any kits are installed per the instructions included
with the kit.
STARTUP CHECK LIST
High Altitude
The UltraSaver can be installed to altitudes up to 10,000 feet in the
U.S. The installation must meet the requirements of the National
Fuel Gas Code or local jurisdictions.
Paint Curing - First Firing
The UltraSaver has been painted with the high quality heat resis-
tant silicon paint. To ensure that the paint is properly cured, allow
the wall furnace to operate on High, for approximately one hour.
During the initial ring of the appliance, it is common for smoke to
appear.
CAUTION
DO NOT touch the surface of the wall furnace, the paint may
soften during the initial operation. Once the paint is cured,
it will not soften again.
To prevent triggering of smoke alarms, supply proper ventila-
tion to the room where the unit is installed.
DO NOT clean the wall furnace with any caustic or abrasive
cleaning solutions. This will damage the surface.
Any damage to the painted surfaces should be repaired only
with authorized paint available from your Empire Dealer.
WIRING
WALL FURNACE INSTALLATION