INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL FAN TYPE Direct Vent Wall Furnace For Installation in Manufactured (Mobile Home), Modular or Residential Homes Patent # 5.664.555 Models DV-20E-5 DV-40E-5 Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
TABLE OF CONTENTS Section Page Important Safety Information...............................................................................................3 Safety Information for Users of LP Gas...............................................................................4 Requirements for Massachusetts..........................................................................................5 Introduction....................................................................................................
IMPORTANT SAFETY INFORMATION This Is a Heating Appliance Do Not Operate This Appliance Without Front Panel Installed. • Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room as the appliance.
SAFETY INFORMTION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point by point with the members of your household. Someday when there may not be a minute to lose, everyone's safety will depend on knowing exactly what to do.
REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 3. SIGNAGE.
INTRODUCTION Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with furnace. 3. Installer should show owner how to start and operate furnace and thermostat. 4.
GAS SUPPLY Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L Inside Diameter Outside Diameter Nat. L.P. Nat. L.P. 0-10 feet 1/2” 3/8” 1/2” 3/8” 0-3 meters 12.7mm 9.5mm 12.7mm 9.5mm 10-40 feet 1/2” 1/2” 5/8” 1/2” 4-12 meters 12.7mm 12.7mm 15.9mm 12.7mm 40-100 feet 1/2” 1/2” 3/4” 1/2” 13-30 meters 12.7mm 12.7mm 19mm 12.7mm 100-150 feet 3/4” 1/2” 7/8” 3/4” 31-46 meters 19mm 12.7mm 22.
GAS CONVERSION INSTRUCTIONS Warning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM (LP) Propane GAS TO NATURAL GAS 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit. 2. Open brass union located between the gas valve and burner box.
CLEARANCES 1. Pick a location on a wall with a clear space of 36" (91.4cm) high by 43" (109cm) wide in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 115 VAC wall receptacle to properly power appliance. 2. Unit is supported by a wall bracket secured to the wall. 3.
Installing Wall Bracket (Figures 5 and 6) After finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the wall. Use the (2) 10 x 1" (25mm) hex-head screws or (2) plastic anchors provided. Drill (2) 5/16" (8mm) diameter holes in wall if plastic anchors are used.
FURNACE INSTALLATION (continued) Be sure to deburr the ends with a file after cutting. Installation is easy after cutting the wall opening secure the vent terminal box in place using the (4) 10 x 1" hex-head screws provided. Locate the box so that the middle exhaust tube is directed toward the furnace exhaust outlet opening. See Figure 8. Attach the black 2" flexible inlet air hose to the bottom 2" connector on the vent box using a hose clamp.
VENT TERMINAL EXHAUST INTAKE SLOPE THE VENT TERMINAL HORIZONTAL RUN DOWNWARD THE OUTSIDE TO DRAIN OUT ANY CONDENSATE SLOPE DOWNWARD 1/4" (6mm) PER FOOT (m) TO DRAIN ANY CONDENSATE OUTSIDE SUPPORT STAP EVERY 5 FT. (1.5m) MIN.
LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. B. Before OPERATING smell all around the appliance area for gas.
WIRING GV = GAS VALVE LS = LIMIT SWITCH FS = FLAME SENSOR XFMR = TRANSFORMER PS = PRESSURE SWITCH IGN = HOT SURFACE IGNITOR ROS = ROLLOUT LIMIT SWITCH OPTIONAL WALL MOUNT THERMOSTAT DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN CORDSET 115 VAC XFMR 115 V WHT BLACK HOT SMOOTH INSULATION ON/OFF POWER SWITCH BLACK NEUTRAL RIBBED INSULATION BLK GRY BRN THERMOSTAT ELECTRONIC INTEGRAL BRN GV 24 V R GRY W RED YEL WHT CIRCULATING AIR BLOWER MOTOR CO
MAINTENANCE Proper Main Burner Flame The proper main burner flame will be a blue primary (inner) flame with a larger, lighter blue secondary (outer) blue flame. Removing Gas Valve 1. Remove front grill assembly. 2. Disconnect manifold union assembly at gas valve. 3. Remove (2) two 24 volt wires from gas valve. Label wires prior to disconnection from gas valve. 4. Remove gas valve from gas valve bracket. Removing Main Burner Orifice(s) 1. Remove front grill assembly. 2.
FURNACE CONTROL BOARD DIAGNOSTICS Fault Sequence Code — Trouble Shooting GUIDE # of Blinks Steady On 1 Flash Fault Condition Control OK Temperature limit switch is open Fault Correction -Check Circulating Air Blower Inlet or Grill Outlet for Blockage, Inducer Blower/Circulating Air Blower Run to Cool Heat Exchanger and Limit -Check for Flame Roll Out Condition Causing Roll Out Limit Switch on Burner Box to Open -Clean Circulating Air Filter 2 Flashes Pressure switch is open with inducer on -Check Heat E
PARTS LIST Please Note: When ordering parts, it is very important that part number and description of part coincide. INDEX NO. PART NO. 1 DV-1378 2 DV-1376 3 R-2521 4 DESCRIPTION INDEX NO. PART NO.
PARTS VIEW Page 18 19562-4-0610
SERVICE NOTES 19562-4-0610 Page 19
EMPIRE Comfort Systems Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.
INSTRUCTIONS POUR L'INSTALLATION ET MANUEL DU PROPRIÉTAIRE RADIATEUR MURAL À CIRCULATION FORCÉE AVEC UN ÉVENT DIRECT Pour l’Installation dans des Maisons Pré-fabriquées (Maison Mobile), Modulaires ou Résidentielles MODÈLES Brevet# 5.664.555 DV-20E-5 DV-40E-5 Installateur: L a i s s e z c e t t e n o t i c e a v e c l’appareil. Consommateur: Conservez cette notice pour consultation ultériure.
LA TABLE DES MATIÈRES Section Page Information Importante de Sécurité............................................................................................................. 3 Information de Sécurité pour les Utilisateurs de Propane........................................................................... 4 Introduction . ............................................................................................................................................... 5 Spécifications ...................
INFORMATION IMPORTANTE DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LE PANNEAU DU DEVANT SOIT INSTALLÉ. • A cause des hautes températures, cet appareil doit être situé dans un endroit non achalandé et loin des meubles et des rideaux. • Les petits enfants doivent être surveillés étroitement lorsqu'ils sont dans le même appartement que l'appareil. L'installation et la réparation doivent être faites par une personne qualifiée.
INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des explosions. Dans son état naturel, le propane est inodore et sans couleur. Peut-être que vous ne connaissez pas toutes les précautions décrites cidessous? Elles peuvent vous protéger ainsi que votre famille contre un accident. Lisez-les attentivement dès maintenant, puis réexaminez les, point par point avec les membres de votre famille.
introduction Introduction Toujours consulter le département de construction de votre région en ce qui regarde les règlements, les codes ou les ordonnances qui s'appliquent à l'installation d'un radiateur mural à évacuation directe. Instructions pour l'Installateur 1. Après l'installation, l'installateur doit laisser le manuel d'instructions au propriétaire. 2. L'installateur doit demander au propriétaire de compléter et poster la carte de guarantie de l'unité de chauffage. 3.
ALIMENTATION EN GAZ Emplacement de l’Alimentation de Gaz Installation d’un Nouveau Robinet Principal pour le Gaz La ligne de gaz peut entrer dans l'appareil soit en venant du plancher ou du mur extérieur. L'ouverture pour la ligne de gaz doit être faite à ce moment. L'emplacement de l'ouverture sera déterminé par la position des solives du plancher et par la valve et le raccord utilisé lors de l'entretien.' Chaque appareil doit avoir son propre robinet manuel de gaz.
LES INSTRUCTIONS POUR LA TRANSFORMATION DES GAZ Attention: Conversion doit être faite par un technicien d'entretien qualifié. Les orifices du brûleur principal et la nouvelle étiquette pour le changement des gaz sont fournis dans l'ensemble de conversion qui est attaché au tuyau de gaz. LES INSTRUCTIONS POUR LA CONVERSION DU GAZ PROPANE (PL) AU GAZ NATUREL 1. Avant de faire la conversion, être certain que l'alimentation de gaz du radiateur est fermée et débrancher le pouvoir électrique de l'unité. EN 2.
ESPACES LIBRES 1. Choisissez un endroit sur un mur qui aura un espace libre de 36” (91.4cm) de haut par 43” (109cm) de large. En choisissant un emplacement, il est nécessaire de fournir l'espace libre adéquat pour l'accès à l'installation et à l'entretien. Pour une adéquate alimentation d'électricité à l'appareil, soyez certain de placer l'unité assez près d'une prise de courant murale de 115 VAC. 2. L'unité est soutenue avec un support mural qui est attaché au mur.
Installation du Support Mural (Figures 5 and 6) Après avoir trouver l'emplacement du radiateur, l'alimentation de gaz et l'évent, le support mural doit être placé et installé. Le support doit être attaché aux montants du mur, si possible, ou accroché solidement au mur. Utiliser les (2) vis à tête hex 10 x 1” (25mm) ou les 2 ancrages en plastique qui sont fournis. Si vous utilisez les ancrages de plastique, percez (2) trous de 5/16” (8mm) de diamètre dans le mur.
Furnace Installation (continued) Soyez certain d'ébarber l'extrémité coupée avec une lime. L'installation sera facile àprès avoir coupé l'ouverture murale. Fixer en place la boîte de l'évent terminal en utilisant les (4) vis à tête hex 10 x 1” vis qui sont fournies. Placez la boîte de façon que le milieu du tuyau d'évacuation soit dirigé vers l'ouverture de la sortie d'évacuation du radiateur. Voir Figure 8.
BORNE DE PASSAGE PRISE ÉCHAPPEMENT BORNE DE PASSAGE PLAT DE SUPPORT COURSE HORIZONTALE DE PENTE DE HAUT EN BAS VERS L'EXTÉRIEUR AU DRAIN HORS DU CONDENSAT COLLIERS DE LA CONDUITE ACCOUPLEMENT EN CAOUTCHOUC AVEC DES COLLIERS DE LA CONDUITE SUPPORT DE SUPPORT DE MUR DE PIPE DE PASSAGE MONTURE SUPÉRIEURE MUR EXTÉRIEUR POUR DES COURSES VERTICALES DE 6FT. OU PLUS, EMPLOIENT Un KIT CONDENSAT De DRAIN ET S'ACCROCHENT JUSQU'Au COUDE D'ÉCHAPPEMENT ET S'ÉCOULENT DANS Le PIÈGE.
INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LIRE AVANT D'ALLUMER AVERTISSEMENT: si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil n'a pas de veilleuse. Il est muni d'un dispositif d'allumage lequel allume automatiquement le brûleur. Ne pas essayer d'allumer le brûleur manuellement. B.
D’INSTALLATION ÉLECTRIQUE SCHÉMA DE CÂBLAGE AVERTISSEMENT: DÉBRANCHER L'ALIMENTATION ÉLECTRIQUE AVANT TOUTE INTERVENTION GV = ROBINET DE GAZ LS = CONTACT FIN DE COURSE FS = CAPTEUR DE FLAMME XFMR = TRANSFORMATEUR PS = MANOCONTACT IGN = ALLUMEUR SURFACE CHAUDE ROS = LIMITEUR RETOUR DE FLAMME THERMOSTAT MURAL EN OPTION DÉBRANCHER LES FILS “R”, “W” ET “C” DU THERMOSTAT INTÉGRAL ET MONTER LE THERMOSTAT COMME INDIQUÉ CORDON 115 VCA XFMR R 115 V WHT 24 V NEUTRE NOIR GAINE CANNELÉE PHASE NOIRE ISOLANT LISS
Maintenance Aspect Convenable de la Flamme du Brûleur Principal La flamme convenable pour le brûleur principal consistera d'une flamme (intérieure) primaire bleue avec une flamme secondaire (extérieure) plus large et d'un bleu plus pâle. TUYAU DE L'ÉCHANGEUR FLAMME PRIMAIRE BRÛLEUR Enlever la Valve de Gaz 1. Enlever l'assemblage du grillage avant. 2. De la valve de gaz, débrancher le raccord du tuyau de gaz. 3. De la valve de gaz, enlever (2) deux fils de 24 volt.
DIAGNOSTIC DU CIRCUIT DE COMMANDE DE CHAUDIÈRE Code d’erreur séquentiel — GUIDE de dépannage Clignotements État d’erreur Correction de l’erreur Allumé en continu Commande OK 1 clignotement Le rupteur thermique est ouvert -Vérifier l’absence d’obstruction de l’admission ou la grille de refoulement de soufflante d’air de chauffage, conduite de soufflante d’induction/air de chauffage vers échangeur et rupteur -Voir s’il y a un retour de flamme causant l’ouverture du limiteur de retour de flamme sur le
FAÇON DE COMMANDER LES PIÈCES DE RÉPARATION Les pièces peuvent être commandées seulement par l'entremise du technicien d'entretien ou du vendeur. Pour de meilleurs résultats, le technicien d'entretien ou le vendeur devrait commander les pièces chez le distributeur. Les pièces peuvent être expédiées directement au technicien d'entretien ou au vendeur. Toutes les pièces énumérées dans la liste ont un numéro de pièce.
VUE DES PIÈCES 19562-3-0610 Page 17
NOTES DE SERVICE Page 18 19562-3-0610
NOTES DE SERVICE 19562-3-0610 Page 19
EMPIRE Comfort Systems Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.