Owner`s manual

26591-1-1209Page 10
Figure 2
Combustible Material




Mantel Chart (Figure 3)
Figure 3
MANTEL
18 3/8”
17 1/8”
14 3/8”
12 3/8”
11 3/8”
10 3/8”
9 3/8”
8 3/8”
7 3/8”
6 3/8”
2 1/4”
1 1/2”
3/4”
8”
6”
4 1/2”
3 3/4”
3”
12” (305mm)
10” (254mm)
TOP EDGEOF FIREPLACE
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
Clearance to Combustibles
Air Drop (End) 1/2" (12.7 mm)
Side 1/2" (12.7 mm)
Floor 0" (0 mm)
Top Stand-off 0" (0 mm)
Top Framing Edge 6 3/8" (161.7 mm)
GLASS FRONT
6 3/8”
SEE MANTLE CHART FOR
MAXIMUM MANTLE DEPTH
2” x4 HEADER
STAND OFF
3” (76 mm) HEIGHT
ABOVE TOPOF
FIREPLACE
NAILING
FLANGES
TOP FRAMING
LEDGE
NON-COMBUSTIBLE
FIRST 6 3/8” (SEE
MAGNIFIED VIEW)
FINISHED WALL
(COMBUSTIBLE)
SEE MANTLE CHART
FOR MINIMUM HEIGHT
OF MANTLE ABOVE UNIT
CLEARANCES
Figure 4a - See Through Fireplace Clearances
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFDOOR)
1 3/4MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFDOOR)
1 3/4MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 4b - Peninsula Fireplace Clearances