Owner`s manual
26591-1-1209 Page 17
INSTALLATION
Note:
Attention:
mantel base.
Attention: If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
panel extending the full width and depth of the appliance. The
vertical dimension must be adjusted when a metal or wood panel
is placed beneath the appliance.
Finishing (Figures 16 and 17)
Finish the walls with the material of your choice. Figure 3 on page
10 shows the minimum vertical and corresponding maximum
horizontal dimensions of mantels or other combustible projections
Only non-combustible materials may be used to cover the black
or modify the air inlet/outlet louvers in any manner.
Provide adequate clearances around air openings into the
combustion chamber.
Caution:
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
Flush Wall Installation - See Through Models
Figure 16
Flush Mount Mantel Installation - See-through Models Only
(Figure 15)
hex-head screws supplied in hardware package to attach nailing
Figure 15
Framing (See Figure 12)
place. Framing should be positioned to accommodate wall covering
constructed of 2 x 4 lumber or heavier. The framing headers may
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS, AND WALL COVERING
DETAILS BEFORE FRAMING CONSTRUCTION
BEGINS.
Framing dimension "A" (Figure 12) includes the clearance
NAIL OR OTHER
SUITABLE FASTENER
FRAMING
63/8”(162 mm)
OF NON-COMBUSTIBLE MATERIAL
FINISHED WALL
FRONT TRIMOR NON-
COMBUSTIBLE MA TERIAL
(INSTALLA TION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149°CSEALANT
MATERIAL (SEALANT IS OPTIONAL)