Owner`s manual
31449-4-1113Page 14
DVX36 DVX42
"A" 40 7/8" 40 7/8"
"B" 39 3/8" 43 3/8"
"C" 19 7/8" 19 7/8"
Attention: Add 3-3/4" to “A” dimensions when using a ush mantel
base.
Figure 14
WARNING
If a base or mantel is not used and the appliance is installed directly
on carpeting, tile or other combustible material other than wood
ooring, it shall be installed on a metal or wood panel extending
the full width and depth of the appliance. The vertical dimension
in Figure 14 must be adjusted when a metal or wood panel is
placed beneath the appliance.
Finishing - See Figures 15 and 16
Finish the walls with the material of your choice. Figure 5 on page 10
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the replace.
Only non-combustible materials may be used to cover the black
replace front.
WARNING
When nishing the replace never obstruct or modify the air
inlet/outlet louvers in any manner. Provide adequate clearances
around air openings into the combustion chamber.
CAUTION
If the joints between the nished wall and the replace surround
(top and sides) are sealed, a 300°F minimum sealant material
must be used. These joints are not required to be sealed. Only
non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the replace surround.
Flush Mount Mantel Installation
The replace must extend 3/4" beyond nished wall surface when
using a ush mount mantel. Refer to Figure 13 to locate nailing
anges on replace sides. Mark and drill two 1/8" holes into replace
side to mount each nailing ange. Use eight 1/2" hex-head screws
supplied in hardware package to attach nailing anges to replace
sides.
NAIL OR OTHER
SUITABLE FASTENER
Figure 13
Attention: When replace is installed in optional full cabinet mantel
or corner mantel the four nailing anges shown in Figure 13 will
not be installed on the side of outer casing. The replace will be
attached to the full cabinet mantel or corner mantel with the two
nailing anges located on the top of the outer casing assembly.
Framing
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the replace standoffs. Refer to Figure 14 for minimum
framing dimensions.
CAUTION
MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING
METHODS, AND WALL COVERING DETAILS BEFORE
FRAMING CONSTRUCTION BEGINS.
Framing dimension "A" includes a six inch clearance for
standoffsonrebox.After installing reboxintoframing,
thenishedwallsurfacemustcoverthesixinchopening
abovetherebox.
INSTALLATION (continued)