Owner`s manual
31449-4-1113Page 28
DVVK-4FV DIRECT VENT TERMINATION KIT
INSTALLATION INSTRUCTIONS
This termination kit can only be used with Empire Comfort Sys-
tems direct vent replaces listed for use with DVVK-4FV Verti-
cal Flex Vent Kit. Please review the instructions packaged with
your replace and verify the replace model number. Check
that this ex vent system is listed for use with your replace
model prior to starting the installation.
Thisventkit maybeinstalledas anOEMinstallation ina
manufacturedhome(USAonly)ormobilehomeandmust
beinstalledinaccordancewiththemanufacturer’sinstruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tioninMobileHomes,CAN/CSAZ240MH.
CAUTION
All Fireplaces listed for use with the DVVK-4FV will operate
safely when installed in accordance with this instruction manu-
al. Read all instructions before starting installation, then follow
these instructions carefully to maximize replace performance
and safety. Report damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV vent kit
with other gas appliances is not allowed. Do not connect this ap-
pliance to a chimney ue servicing a separate solid fuel-burning
appliance.
WARNING
Failuretofollowtheseinstructionsmaycreateapossible
rehazardandwillvoidthewarranty.
WARNING
Always maintain minimum clearances around vent systems.
The minimum clearance to combustibles for horizontal runs of
vent pipe is 3 inches from the top, and 1 inch from the sides
and bottom of the vent system. Do not pack the open air spaces
around the replace or ue with insulation or other materials.
Any horizontal run must have a 1/4” rise for every one foot of
run towards the vent termination. The vent above the roof must
terminate vertically.
WARNING
ContactyourLocalBuildingandFireOfcialsaboutrestric-
tions and installation inspections in your area.
IMPORTANT SAFETY INFORMATION
• The vertical termination cap MUST be vented directly to the
outside. The termination kit MUST NEVER be connected to a
chimney ue(s) servicing a separate solid-fuel burning appli-
ance or any other appliances.
• Termination cap MUST NOT be mounted horizontally.
• The exible vent pipe cannot be intermingled with any of the
rigid vent pipe section(s). DO NOT connect two sections of
exible vent pipe together to achieve a longer length without
the use of approved connectors.
• The installation must conform with local codes or in the ab-
sence of local codes, with the National Fuel Gas Code, ANSI
Z223.1 (in the United States) or with the current installation
code CAN/CGA B149 (in Canada).
• Only Direct Vent replaces approved for use with Empire
Comfort Systems, Inc. DVVK-4FV termination kit shall be
used. See PARTS LIST/ILLUSTRATIONS section for vent
component identication.
• Horizontal vent runs must be supported every 2 feet using
wall straps. Vertical runs must be supported every 3 feet using
wall straps. Slip wall straps loosely on to pipe. Attach installer
provided straps to framing members using nails or screws.
• The replace and venting system should be inspected before
initial use and at least annually by a qualied eld service per-
son. Inspect the external vent cap on a regular basis to make
sure that no debris is interfering with the airow. Inspect entire
venting system to ensure proper function.
• Please refer to the replace instructions for information on
Termination Cap clearances.