Owner`s manual
31449-4-1113 Page 37
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)
7. Remove outside mounting plate with tube attached from wall.
Mark and cut the extra length of the 6 5/8” (168mm) diameter
tube from the opposite end. Do not crimp or enlarge tube.
8. Attach the 4” (102mm) diameter ue outlet tube onto the rigid
venting system or directly to replace. Ensure the 4” (102mm)
diameter ue outlet tube is placed as far as possible onto the
rigid venting system. Mark the 4” (102mm) diameter ue outlet
tube 2 1/2” (64mm) beyond the vinyl siding kit or wall. See
Figure 56. Remove the 4” (102mm) diameter ue outlet tube
from rigid venting system. When installing directly to replace,
tape gasket needs to be used.
Figure 56
9. Mark or wrap tape completely around the tubes at the marked
points to help in making a true cut. Do not crimp or enlarge
tubes.
10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/
mounting plate onto end of rigid venting system to correct posi-
tion. Fasten the outside mounting plate to the vinyl siding kit or
wall with 10 x 1 1/2” screws. (Ensure upward slope).
11. From inside: Attach the inlet tube to the collar on the back of the
replace (or the rigid venting system) using three self tapping
screws.
Figure 57
12. Seal the 4” (102mm) diameter ue outlet tube. Follow instruc-
tions and diagram. See Figure 58.
13. Fasten 4” (102mm) diameter ue outlet tube in place. Do not
“twist” the ue outlet tube into the replace collar (or rigid vent-
ing system). Hold the tube by the seam and push in using a
perpendicular “rocking” motion. This ensures the seam on the
tube stay intact.
14. Fasten vent cap end using three 10 x 1/2” screws to mounting
plate.
Sealing4”(102mm)DiameterFlueOutletTube
1
”
VENT CAP END
APPLY
SEALANT
ON THE INSIDE
DO NOT PLACE
OVERLAPPED
SECTION OVER
THE SEAM IN THE TUBE
Figure 58
Note: Tape gasket to be applied prior to installing to replace ue
outlet tube only. Tape gasket should not be used when mating the
ue outlet tube to a rigid venting system.