Owner`s manual

31449-4-1113Page 8
VENT SYSTEM IDENTIFICATION
Figure 1
Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
replace is to be vented out the top or out the rear.
NOTICE: Some replaces cannot be vented out the rear of the
replace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
Special Venting Components (Simpson Duravent)
SeeEmpireComfortSystemsRetailPriceListforSimpsonDuraventpartnumbersandpricing.
Special DV Vent Kits for DVX36
AvailablefromEmpireComfortSystems,Inc.dealers.
DVVK-4VP (DVVK-4V) Direct-Vent Fireplace Vent Kit - Vertical, Includes SD-991, SD-953, and SD-943
DVVK-4TP (DVVK-4T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to 11 inch wall thickness, Includes SD-911,
SD-985, SD-990 and SD-942
DVVK-4TSP (DVVK-4TS)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to 7 inch wall thickness, Includes SD908,
SD-985, SD-990 and SD-942
DVVK-4FV Direct-Vent Fireplace Vertical Flex Vent Kit
DVVK-4RE Direct-Vent Fireplace Vent Kit, Thru-the-wall, 5 to 13 3/4 inch wall thickness
Special DV Vent Kits for DVX42
AvailablefromEmpireComfortSystems,Inc.dealers.
DVVK-5RP (DVVK-5R)
Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall thickness, Includes SD-1208, SD-1247,
and SD-2184
DVVK-5TP (DVVK-5T)
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4 to 6 inch wall thickness, Includes SD-1290,
SD-1284, SD-1208 and SD-1247
DVVK-5VP (DVVK-5V) Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291, SD-1253, and SD-1243
DVVK-5TS Top Vent Kit (Horizontal) - 4½" to 6" wall thickness (114.3mm to 152mm)
DVVK-5F Horizontal Flex Vent Kit (4' Flex) (1.22m)
Note: DVX42FP appliances can use the DVVK-4 vent systems only if using a DVA47 adaptor.
When selecting a vent system for use with the replace, refer to
the “Special Vent Systems” section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use Figure 20 on page 17 for top venting to eliminate issues after
installation. Check pipe diameter on vent system and replace to
verify the size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C.Theinneruejointsdonotrequireanysealant.
*Note: If using three 90° elbows during horizontal
termination, see Figure 28.