Owner`s manual

30329-0-0312Page 12
DVX36 DVX42
"A" 40 7/8" 40 7/8"
"B" 39 3/8" 43 3/8"
"C" 19 7/8" 19 7/8"
Figure 13
Attention: If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
other than wood ooring, it shall be installed on a metal or wood
panel extending the full width and depth of the appliance. The
vertical dimension in Figure 13 must be adjusted when a metal or
wood panel is placed beneath the appliance.
Finishing(Figures14and15)
Finish the walls with the material of your choice. Figure 4 on page 8
shows the minimum vertical and corresponding maximum horizontal
dimensions of mantels or other combustible projections above the
top front edge of the replace.
Only non-combustible materials may be used to cover the black
replace front.
Warning: When nishing the replace never obstruct or modify
the air inlet/outlet louvers in any manner. Provide adequate
clearances around air openings into the combustion chamber.
Caution: If the joints between the nished wall and the replace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive if
needed), can be applied as facing to the replace surround.
FlushMountMantelInstallation(Figure12)
The replace must extend 3/4" beyond nished wall surface when
using a ush mount mantel. Refer to Figure 12 to locate nailing
anges on replace sides. Mark and drill two (2) 1/8" holes into
replace side to mount each nailing ange. Use eight (8) 1/2" hex-
head screws supplied in hardware package to attach nailing anges
to replace sides.
NAIL OR OTHER
SUITABLE FASTENER
Figure 12
Framing(Figure13)
Fireplace framing can be built before or after the replace is set in
place. Framing should be positioned to accommodate wall covering
and replace facing material. The replace framing should be
constructed of 2 x 4 lumber or heavier. The framing headers may
rest on the replace standoffs. Refer to Figure 13 for minimum
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMINGMETHODS,ANDWALLCOVERINGDETAILSBEFORE
FRAMING CONSTRUCTION BEGINS.
Framing dimension "A" includes a six inch clearance for
standoffsonrebox.Afterinstallingreboxintoframing,
thenishedwallsurfacemustcoverthesixinchopening
abovetherebox.