Owner`s manual

30329-0-0312Page 22
Installation Instructions
This termination kit can only be used with Empire Comfort Systems direct vent replaces listed for use with
DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your replace and verify the
replace model number. Check that this ex vent system is listed for use with your replace model prior to
starting the installation.
IMPORTANT SAFETY INFORMATION
The vertical termination cap MUST be vented directly to the
outside. The termination kit MUST NEVER be connected to a
chimney ue(s) servicing a separate solid-fuel burning appli-
ance or any other appliances.
Vertical termination cap MUST NOT be mounted horizontally.
The exible vent pipe cannot be intermingled with any of the
rigid vent pipe section(s). DO NOT connect two sections of
exible vent pipe together to achieve a longer length without
the use of approved connectors.
The installation must conform with local codes or in the ab-
sence of local codes, with the National Fuel Gas Code, ANSI
Z223.1 (in the United States) or with the current installation
code CAN/CGA B149 (in Canada).
Only Direct Vent replaces approved for use with Empire
Comfort Systems, Inc. DVVK-4FV termination kit shall be
used. See PARTS LIST/ILLUSTRATIONS section for vent
component identication.
Horizontal vent runs must be supported every 2 feet using
wall straps. Vertical runs must be supported every 3 feet using
wall straps. Slip wall straps loosely on to pipe. Attach installer
provided straps to framing members using nails or screws.
The replace and venting system should be inspected before
initial use and at least annually by a qualied eld service per-
son. Inspect the external vent cap on a regular basis to make
sure that no debris is interfering with the airow. Inspect entire
venting system to ensure proper function.
Please refer to the replace instructions for information on
Termination Cap clearances.
ThisventkitmaybeinstalledasanOEMinstallationinamanufacturedhome(USAonly)ormobile
homeandmustbeinstalledinaccordancewiththemanufacturersinstructionsandthemanufactured
homeconstructionandsafetystandard,Title24CFR,Part3280orStandardforInstallationinMobile
Homes,CAN/CSAZ240MH.
CAUTION
All Fireplaces listed for use with the DVVK-4FV will operate safely when installed in accordance with this instruction manual. Read all
instructions before starting installation, then follow these instructions carefully to maximize replace performance and safety. Report
damaged parts to your dealer.
WARNING
Any common venting of the gas appliance using the DV vent kit with other gas appliances is not allowed. Do not connect this appliance
to a chimney ue servicing a separate solid fuel-burning appliance.
WARNING
Failuretofollowtheseinstructionsmaycreateapossiblerehazardandwillvoidthewarranty.
WARNING
Always maintain minimum clearances around vent systems. The minimum clearance to combustibles for horizontal runs of vent pipe is
3 inches from the top, and 1 inch from the sides and bottom of the vent system. Do not pack the open air spaces around the replace or
ue with insulation or other materials. Any horizontal run must have a 1/4” rise for every one (1) foot of run towards the vent termination.
The vent above the roof must terminate vertically.
WARNING
ContactyourLocalBuildingandFireOfcialsaboutrestrictionsandinstallationinspectionsinyourarea.
DVVK-4FVDIRECTVENTTERMINATIONKIT