Owner`s manual
30329-0-0312 Page 7
Figure 1
Remote Control Options
& Accessories
Description
FRBC Millivolt Battery Remote ON/OFF
FRBTC Millivolt Battery Remote T-Stat
TMV Millivolt WIRELESS Wall Thermostat
TRW Millivolt REED SWITCH Wall Thermostat
FWS-1 Millivolt Wall Switch
FREC Electric Remote
FBB4 Complete Blower Assembly (MV Only)
NOTE: Air shutter settings are factory minimum settings. Some venting congurations may require minor air shutter adjustments for
optimum performance.
SPECIFICATIONS
FIREPLACE DIMENSIONS
DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP
Input Btu/hr Maximum 35,000 30,000 37,500 35,000
Btu/hr Minimum 24,000 21,000 26,000 24,000
KWH (Maximum) 10.3 8.8 11.0 10.3
(Minimum) 7.2 6.2 7.6 7.2
Orice #32 (P-211) 1.65mm (P-250)
#31 (P-209) -
DVX42FP(3,7,9)
2.75 mm (P-305) - DVX42FP5
#50 (P-245) - DVX42FP(3,7,9)
1.80 mm (P-304) - DVX42FP5
Air Shutter Opening 1/4"(6.4mm) FULL OPEN 1/4" (6.4mm) FULL OPEN
Height without standoff 34 3/4 (3.2mm) 34 3/4" (3.2mm) 34 3/4" (3.2mm) 34 3/4" (3.2mm)
Width 39 3/8" (1,000mm) 39 3/8" (1,000mm) 43 3/8" (1,101mm) 43 3/8" (1,101mm)
Depth 19 7/8" (505mm) 19 7/8" (505mm) 19 7/8" (505mm) 19 7/8" (505mm)
Gas Inlet Shutoff Valve (Pipe) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
DVX Dimensions
Dimension DVX36FP DVX42FP
A 34 3/4"
882.7mm
34 3/4"
882.7
B 39"
990.6mm
43"
1092.2mm
C 19 7/8"
505mm
19 7/8"
505mm
D 25"
635mm
25"
635mm
E 36"
914.4mm
40"
1016mm
G 26 1/2"
673.1mm
26 1/2"
673.1mm
H 40 3/4"
1035.1mm
40 3/4"
1035.1mm
I 13 1/4"
336.6mm
13 1/4"
336.6mm
J 7 1/8"
181mm
7 1/8"
181mm