Owner`s manual

30329-0-0312Page 8
MantelChart(Figure4)
MANTEL
19”
18 3/4”
17”
16”
15”
14”
13”
12”
11
10”
2 1/4”
1 1/2”
3/4”
8”
6”
4 1/2”
3 3/4”
3”
12” (305mm)
10” (254mm)
TOP EDGEOF FIREPLACE
COMBUSTIBLE TRIM AND MANTELS
ALLOWED IN SHADED AREA
Figure 4
Clearances(Figure5)
Clearance from top front edge of replace to ceiling is 36"
Clearance from side of replace to adjacent sidewall is 6".
36”
(914mm)
6” (152mm)
Figure 5
Figure 2
CombustibleMaterial
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the replace. The ow of heat can
ignite combustibles.
Clearance to Combustibles
Back 0" (0 mm)
Side 0" (0 mm)
Floor 0" (0 mm)
Top Stand-off 0" (0 mm)
Top Framing Edge 6" (152 mm)
CLEARANCES