Operator's Manual

7
NAVIGATING THROUGH SETTINGS
Once in Settings Mode, use the Trigger is used to navigate to the next setting, where the LED
indicates which setting as listed in the chart below. Pressing and releasing the Trigger quickly
will navigate to the next setting.
The LED color/status will change accordingly.
Example: If currently in Firing Mode (solid Red), press and release the Trigger 3 times to get to
De-Bounce (flashing Red).
- LED Settings
- Solid Red................................................Firing Mode
- Solid Green............................................Max ROF
- Solid Amber...........................................Dwell
- Flashing Red..........................................De-Bounce
- Flashing Green.......................................Ball In Place
- Flashing Amber......................................Ramp Start
- Fast Flashing Red..................................Ramp Sustain
CHANGING SETTINGS
To change a setting, first navigate to the setting you would like to change by using the Trigger
as described above. Once at the desired function, press and hold the Trigger for 2 seconds.
The LED will then begin blinking to indicate the setting’s current value. Once the blinking stops,
the LED will turn off and you have a 3 second window to begin entering a new value. Press and
release the Trigger the number of times corresponding to the desired new setting value. After the
desired number is reached, release the Trigger and after 3 seconds the LED will cycle through an
array of colors to indicate the setting is saved. If you do not enter any Trigger pulls to modify a set-
ting, the value remains the same. If you enter more than maximum amount of Trigger pulls for any
setting, the value will become the maximum value for that setting. Power off the marker to exit
the Settings Mode. Any setting that was modified will be stored and ready to use upon startup.
FIRING MODES
- INDICATED BY SOLID RED LED
You must be in the Settings Mode to change Firing Modes, see above for instructions on how
to enter Settings Mode. After choosing Firing Modes (Solid Red), hold the Trigger, the LED will
flash Red LED blinks equal to the current setting, followed by a pause. Pull the Trigger the num-
ber of times equal to your new desired setting (see chart below). Once done, the LED will cycle
through an array of colors to indicate the setting is saved and return to the Settings Mode. There
are 4 firing modes available: NPPL/Semi Auto, PSP/Burst, Millennium/Ramp, and NXL Style
Full Auto.
IMPORTANT: When the Firing Mode is changed it will also automatically modify the correspond-
ing Max Rate of Fire and ramping parameters that correspond to that mode. These settings may be
changed after Firing Mode is selected
#Number of Blinks Mode
- 1 NPPL/Semi
- 2 PSP/Burst
- 3 Mill/Ramp
- 4 Full Auto
NPPL/Semi Auto: Marker will shoot 1 time for each time the Trigger is pulled.
The default setting meets 2011 NPPL marker rules.
Default: Max ROF = 15.0bps
PSP/Burst: Marker will shoot in semi-auto mode equal to the number of shots specified by the
Ramp Start setting (see below for more information), then will go into a 3-shot burst at the Max
ROF setting. If the marker is not fired for 1 second, the marker will shoot semi-auto until Ramp Start
is again achieved.
The default setting meets 2011 PSP marker rules.
Default: Max ROF = 12.0bps; Ramp Start=3shots
Millennium/Ramping: Marker will shoot in semi-auto mode equal to the number of shots speci-
fied by the Ramp Start setting, and if the Ramp Sustain ROF (see below for more information) is
achieved, the marker will ramp up to the Max ROF setting. If the marker is not fired for 1 second the
marker will shoot semi-auto until ramping parameters are achieved. The default setting meets 2011
Millennium marker rules.
Default: Max ROF = 10.0bps; Ramp Start = 3shots; Ramp Sustain = 6tps(Trigger pulls per sec-
ond)
NXL Style Full Auto: Marker will shoot in semi-auto mode equal to the number of shots specified by
the Ramp Start setting, then will go into full automatic mode as long as the Trigger is held down.
If the marker is not fired for 1 second the marker will then shoot semi-auto again until Ramp Start
is achieved again
Default: Max ROF=12.0bps; Ramp Start = 3shots