Operator's Manual
8
MAX RATE OF FIRE (ROF)
- INDICATED BY SOLID GREEN LED
This setting controls the maximum number of paintball per second the marker is allowed to fire.
The setting can be varied from 8 to 20 balls per second (bps) in 0.5bps intervals. Use the chart
below to set the Max ROF.
Default: Max ROF = 15.0 bps
You must be in the Settings Mode to change the Max ROF, see above for instructions on how to
enter Settings Mode. After choosing Max ROF Mode (Solid Green), hold the Trigger to get into
the Mode, the LED will flash GREEN LED blinks equal to the current setting, followed by a pause.
Pull the Trigger the number of times equal to your new desired setting (see chart below). Once
done, the LED will cycle through an array of colors to indicate the setting is saved and return to
the Settings Mode.
Example: 10 LED blinks = 12.5 BPS
# of Blinks BPS Value # of Blinks BPS Value # of Blinks BPS Value
1 8.0 10 12.5 18 16.5
2 8.5 11 13.0 19 17.0
3 9.0 12 13.5 20 17.5
4 9.5 13 14.0 21 18.0
5 10.0 14 14.5 22 18.5
6 10.5 15 15.0 23 19.0
7 11.0 16 15.5 24 19.5
8 11.5 17 16.0 25 20.0
9 12.0
DWELL SETTING
- WILL BE INDICATED BY SOLID AMBER LED
This setting controls the amount of time the solenoid valve is left open. A setting too high will
waste excess gas and affect efficiency. A setting too low will prevent marker from operating
properly. It is not recommended to change this setting unless you are an experienced user. Mini-
mum dwell time is 3.0ms and is increased in .5ms increments up to 10ms. Use the chart below
to set the Dwell.
Default: Dwell = 8.0 ms
You must be in the Settings Mode to change the Dwell Setting, see above for instructions on how
to enter Settings Mode. After choosing Dwell Setting (Solid Amber), hold the Trigger to get into
the Mode, the LED will flash Amber LED blinks equal to the current setting, followed by a pause.
Pull the Trigger the number of times equal to your new desired setting (see chart below). Once
done, the LED will cycle through an array of colors to indicate the setting is saved and return to
the Settings Mode.
# of Blinks Dwell in ms # of Blinks Dwell in ms
1 3.0 9 7.0
2 3.5 10 7.5
3 4.0 11 8.0
4 4.5 12 8.5
5 5.0 13 9.0
6 5.5 14 9.5
7 6.0 15 10.0
8 6.5
TRIGGER DE-BOUNCE
- WILL BE INDICATED BY A FLASHING RED LED
Time in milliseconds the Trigger pull must be released before the next Trigger pull can be reg-
istered. This eliminates electronic noise and vibrations (“Trigger Bounce”) that the board may
wrongly interpret as a Trigger action (Trigger pull) and fire the marker. A higher setting will re-
duce the bounce. A lower setting will allow for more bounce. One blink corresponds to 1ms of
De-Bounce time. De-Bounce is adjustable from 1-15ms in 1.0ms increments.
Default: De-Bounce = 5.0 ms
You must be in the Settings Mode to change the De-Bounce Setting, see above for instructions
on how to enter Settings Mode. After choosing De-Bounce Setting (Flashing Red), hold the Trig-
ger to display the value, the LED will show flashing Red LED blinks equal to the current value,
followed by a pause. Pull the Trigger the number of times equal to your new desired setting, one
pull per desired setting equal to each millisecond. Once done, the LED will cycle through an array
of colors to indicate the setting is saved and return to the Settings Mode.
BALL IN PLACE (BIP) DELAY
- WILL BE INDICATED BY A FLASHING GREEN LED
Time in milliseconds the ball must stay in breech before it can be fired. Increase this setting for
slower feeding loaders to avoid chopping balls in the breech. Faster force feed loader systems