SPECIFICATIONS
DVL25IN(3,7)3L MODELS LP Nat
Input Btu/hr Maximum 20,000 20,000
Btu/hr Minimum 16,000 14,000
KWH (Maximum) 5.9 5.9
(Minimum) 4.4 4.4
Orice 1.35mm 2.20mm
Air Shutter Opening 5/16” CLOSED
DVL33IN(3,7)3L MODELS LP Nat
Input Btu/hr Maximum 27,000 27,000
Btu/hr Minimum 22,000 19,000
KWH (Maximum) 7.83 7.83
(Minimum) 6.5 5.51
Orice 1.55mm #39 (.0995)
Air Shutter Opening 5/16” 3/32”
VentingKits Description Contents
DVKI Vertical Vent Kit - 17 1/2’ One piece of 35’ FlexVent (split for 17 1/2’ vent run), Round Cap, Flashing, connectors,
and clamps.
Recommended when installing to an existing round replace chimney pipe.
DVVK3FV Vertical Vent Kit - 25’ Two pieces of 25’ FlexVent, Rectangle Cap, Flashing, connectors, and clamps
Recommended when installing to a square or rectangular clay ue.
DVK35 Vent Extension Kit 35’ ex vent extension section with 2 connectors and 4 clamps
NOTICE: When installing vent caps, special locally made ashings may be required to properly seal the vent system to the existing
chimney termination.
RemoteControl
Accessories
Description
FRBC Millivolt Battery Remote ON/OFF
FRBTC Millivolt Battery Remote Thermostat
TRW Millivolt WIRELESS Wall Thermostat
TMV Millivolt Reed Switch Wall Thermostat
FWS-1 Millivolt Wall Switch
SurroundKits Description
4SidedContemporary-StainlessSteelTop&Bottom,
BlackSides
S2562BLSS Stainless Steel, Black, for use on DVL25IN
models
S3362BLSS Stainless Steel, Black for use on DVL33IN
models
4SidedTraditionalBlack
S2562BL Black for use on DVL25IN models
S3362BL Black for use on DVL33IN models
SH-1-BL Shroud (For replace openings up to 48” x 36” -
Requires surround.)