Specifications

12
BIP (BALL IN PLACE) DELAY
- WILL BE INDICATED BY A QUICK FLASHING
RED LED
To get into the BIP Function, make sure the
Power is Off, then push the Function Key 4
times. The LED will quickly flash red to indicate
that you are in the BIP Function. Then the LED
will slowly flash to indicate the BIP Setting that
you are currently using.
Default is (5) (One Flash = 1 millisecond). BIP
is adjustable from 1 to 40 milliseconds. This
Function is also controlled through the same
techniques used for Firing Modes and ROF
Functions. While the LED is Red, increase or
decrease your BIP in 1 milliseconds increments.
Note: If you are not using a force-feed loader, it is
recommended that you use a higher BIP setting.
RAMPING POINT
-WILL BE INDICATED BY QUICK FLASHING GREEN LED
To get into the Ramping Point function make sure the Power is Off, then
push the Function button 5 times and the LED will turn to a quickly flashing
green and then slowly flash too indicate the ramping point setting you are
currently using. The default ramping point for PSP firing mode is 8 (4 BPS).
The default ramping point when firing mode is changed to millennium firing
mode is 10 (5.0 BPS). Ramping Point is adjustable from (3 to 9.0 BPS).
Please see chart for corresponding flashes and BPS settings.
FLASHES/ROF
1 Flash = 8.0 BPS
2 Flash = 8.5 BPS
3 Flash = 9.0 BPS
4 Flash = 9.5 BPS
5 Flash = 10 BPS
6 Flash = 10.5 BPS
7 Flash = 11.0 BPS
8 Flash = 11.5 BPS
9 Flash = 12.0 BPS
10 Flash = 12.5 BPS
11 Flash = 13.0 BPS
12 Flash = 13.5 BPS
13 Flash = 14.0 BPS
14 Flash = 14.5 BPS
15 Flash = 15.0 BPS
16 Flash = 15.5 BPS
17 Flash = 16.0 BPS
18 Flash = 16.5 BPS
19 Flash = 17.0 BPS
20 Flash = 17.5 BPS
21 Flash = 18.0 BPS
22 Flash = 18.5 BPS
23 Flash = 19.0 BPS
24 Flash = 19.5 BPS
25 Flash = 20.0 BPS
FACTORY BOARD RESET
There are 3 ways to reset the Optimus™ board to default factory settings.
Turn the power Off then push the Function Key and Power Button at the
same time.
Remove the battery then simultaneously push and hold the Function Key
and Power Button for a full 10 seconds.
- Disconnect the battery and leave it idle for 15 seconds.
BOARD DEFAULTS
1. Firing Modes – 1 blink (Semi-auto)
2. Rate-of-Fire – 25 blinks (20 bps)
3. Dwell - 28 blinks (7 ms)
4. BIP Delay – 5 blinks (5 ms)
5. Ramping Point – 8 blinks (4 bps)
RAMPING POINTS
Flashes/PTR (Pulls to Ramp)
6 Flash = 3 BPS
7 Flash = 3.5 BPS
8 Flash = 4 BPS
9 Flash = 4.5 BPS
10 Flash = 5 BPS
11 Flash = 5.5 BPS
12 Flash = 6 BPS
13 Flash = 6.5 BPS
14 Flash = 7 BPS
15 Flash = 7.5 BPS
16 Flash = 8 BPS
17 Flash = 8.5 BPS
18 Flash = 9 BPS