Owner`s manual
28040-3-0511 Page 25
B. BEFORE LIGHTING
WHAT TO DO IF YOU SMELL GAS
C. Use only your hand to push in or turn the gas control
1. Openbottomlouverassembly(ifapplicable).
2. Set REMOTE/OFF/ON switch to OFF.
3. Turn off all electric power to the appliance if service is to be
performed(ifapplicable).
4. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
5. Closebottomlouverassembly(ifapplicable).
1. STOP! Read the safety information above.
2. Openbottomlouverassembly,(if
applicable).
3. Set REMOTE/OFF/ON switch to
"OFF."
4. Turn off all electric power to the
appliance(ifapplicable).
5. Push in gas control knob slightly
and turn clockwise to
"OFF."
6. Wait ten (10) minutes to clear out any gas.
Thensmellforgas,includingneartheoor.If
you smell gas, STOP! Follow "B" in the safety
information above. If you do not
smell gas, go to the next step.
7. Find pilot - Follow metal tube from
gas control. The pilot is located
next to the burner, near the right
side.
8. Turn gas control knob counter-
clockwise to "PILOT."
9. Push in control knob all the way
and hold in. Repeatedly push the Piezo Ignitor Button until the
pilot is lit. Continue to hold the control knob in for about one
(1)minuteafterthepilotislit.Releaseknob,anditwillpop
back up. Pilot should remain lit. If it goes out, repeat steps 5
through 9.
• Ifknobdoesnotpopupwhenreleased,STOPandIM-
MEDIATELY call a qualied service technician or gas
supplier.
• Ifthepilotwillnotstaylitafterseveraltries,turnthegas
control knob to "OFF" and call your service technician or
gas supplier.
10. Turn gas control knob counterclockwise to "ON."
11. Set REMOTE/OFF/ON switch to desired setting.
12. Turnonallelectricpowertotheappliance(ifapplicable).
13. Closebottomlouverassembly(ifapplicable).
OFF
PILOT
ON
GAS CONTROL KNOB
SHOWNIN "OFF" POSITION.
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
GAS CONTROL KNOB
SHOWN IN "OFF" POSITION.
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOPILE
REMOTE
OFF
ON
THERMOCOUPLE
(LPG)
10,000 BTU MILLIVOLT CONTROL VALVE LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
WARNING: