Owner`s manual

28040-3-0511Page 26
WARNING:

 


WHAT TO DO IF YOU SMELL GAS
 
 

 

       

B. Use only your hand to push in or turn the gas control
           



 



FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Openbottomlouverassembly,(ifapplicable).
3. Pressthe"I/O"(ON/OFF)buttononthevalvefaceto"OFF."
4. Waitve(5)minutestoclearoutanygas,thensmellforgas
includingneartheoor.Ifyousmellgas,STOP!FOLLOW
"B"inthesafetyinformationabove.Ifyoudon'tsmellgas,go
to the next step.
LIGHTING PROCEDURE - HANDSET METHOD
1. Turn control arrow on valve face to "ON." Press the "I/O" but-
ton to "I." Press the "OFF" and "UP" buttons on the handset,
rmlyatthesametime.Along"beep"willsound,followedby
5 short "beeps." Ignitor will spark and will continue until pilot
is lit. For full Remote Control operation see Appliance Instal-
lation manual.
LIGHTING PROCEDURE - MANUAL METHOD
1. Pressthe"I/O"(ON/OFF)buttonto"I."
2. Turn control arrow on valve face to "MAN."
3. Using a small bladed screwdriver, press and hold button
within hold on control. Manual depress piezo igniter button to
light pilot. If pilot does not light, steps 2-3 can be immediately
repeated. If the pilot will not stay lit after several tries, follow
the instructions "To Turn Off Gas to Appliance" and call your
service technician or gas supplier.
4. Whenthepilotislitandstable,turnameheightcontrolknob
counterclockwise and the main burner will ignite.
Toadjustameheight,turnameheightcontrolknob.
CORRECT PILOT FLAME
INCORRECT PILOT FLAME
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)
ELECTRODE
PILOT
THERMOCOUPLE
(LPG)
“I/O”
(ON/OFF)
SWITCH
MAN
NO
75
O
F
SET
OFF
Press firmly
at same time
PRESS IN
& HOLD
MAN
TO IGNITE PILOT
HANDSET MODE
To Ignite Burner
MANUAL MODE
PIEZO
IGNITER
TO TURN OFF GAS TO APPLIANCE
MANUAL MODE-Toturnoffmainburner,turnameheightcontrolknobfullyclockwise . To fully shut down, press "I/O"
button to "O."
HANDSET MODE - Press "OFF" button on handset. To fully shut down, press "I/O" button to "O."
INTERMITTENT PILOT LIGHTING INSTRUCTIONS