CLEARANCES
Sidewall Clearances:Theclearancefromtheinsideoftherebox
to perpendicular combustible side wall should not be less than 1
3/4". See Figures 1a and 1b.
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD
)
1 3/4”MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 1a - See Through Firebox Clearances
36”
MIN.
42”
MIN.
(CEILING TO
TOPOFHOOD
)
1 3/4”MIN.
PERPENDICULAR
COMBUSTIBLE
SIDEWALL
Figure 1b - Peninsula Firebox Clearances
Combustible material clearance from front of rebox: 36"
minimum
Firebox Side and Back Clearances: The rebox outer casing
side(s) require a minimum 1/2" clearance to combustibles.
Top Framing and Finishing: Combustible framing may rest on
topofstandoffs.Combustiblenishingmaterialsmayextendtothe
top standoff screws on the front edge of the top outer wrap. See
Figures 2a and 2b.
Figure 2a - Louvered Models
FIREBOX
STAND OFF
COMBUSTIBLE
FINISHED WALL
OR MANTEL
2X4
HEADER
TOP OUTER
WRAP
FINISH WITH TRIM KIT
OR NON-COMBUSTIBLE
MATERIAL AS DESIRED.
Figure 2b - Flush Models