Owner`s manual

27451-5-0614 Page 5
CLEARANCES
Ceiling Clearances: The ceiling height should not be less than 42"
from the top of the hood. See Figures 3a and 3b.
MANTEL
STANDARD
HOOD
17 ½”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
8”
5”
0”
9”
11
13”
15”
Figure 3a - Mantel Clearances with Standard Hood
MANTEL
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
8”
MIN.
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
22”
8”
20”
18”
5”
16”
14 ½”
24 ½”
0”
FIREBOX
FACE
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
Figure 3b - Mantel Clearances with Optional Extended Hood
Mantel Clearances: Ventfreereboxmodelsmustusethehood
suppliedwiththerebox,oroneoftheoptionalhoodkitsavailable
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Grate Clearance: The minimum clearance between the front legs
ofthegrateandthefrontedgesofthereboxis11/2".