CLEARANCES
Ceiling Clearances: The ceiling height should not be less than 42"
from the top of the hood. See Figures 3a and 3b.
MANTEL
STANDARD
HOOD
17 ½”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
4½”
MIN.
FIREBOX
FACE
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
8”
6½”
5”
3½”
1½”
0”
6½”
9”
11”
13”
15”
Figure 3a - Mantel Clearances with Standard Hood
MANTEL
13”
10”
12”
MAX
42”
MIN.
(CEILING TO
TOPOF HOOD)
8”
MIN.
84”
MIN.
(CEILING TO FLOOR)
CEILING
COMBUSTIBLES
ALLOWED
22”
8”
20”
6½”
18”
5”
16”
3½”
14 ½”
2½”
24 ½”
0”
FIREBOX
FACE
EXTENDED HOOD
(VB4H SERIES)
(NOT AVAILABLE ON
PENINSULA OPEN END)
3/8” COMBUSTIBLE
CLEARANCE REQUIRED
FROM TOP EDGE
OF FIREBOX
Figure 3b - Mantel Clearances with Optional Extended Hood
Mantel Clearances: Ventfreereboxmodelsmustusethehood
suppliedwiththerebox,oroneoftheoptionalhoodkitsavailable
for each model. If a combustible mantel is installed, it must meet
the clearance requirements detailed below.
Grate Clearance: The minimum clearance between the front legs
ofthegrateandthefrontedgesofthereboxis11/2".