Owner`s manual

27451-6-0614Page 6
FIREBOX INSTALLATION INSTRUCTIONS
Any vent-free Gas Log Heater must be “For use with approved ANSI
Z21.11.2 unvented room heater.”
Follow and complete the installation instructions of the gas log set
andtherequirementsofthisrebox.
Checkallttingsforleaksbeforelightingthegaslogset.
Inplanningtheinstallationfortherebox,itisnecessarytodetermine
where the unit is to be installed and whether optional accessories
are desired. Gas supply piping should also be planned at this time.
A gas shut off must be in this line.
Thereboxcanbemountedonanyofthesesurfaces:
1. Aathardcombustibleornon-combustiblesurface.
2. A raised platform of combustible or non-combustible material.
3. Recessedintotheoorasillustratedby Figure 4.
4. Supportedunderall(4)cornersofthereboxsothatcontact
is made on all four perimeter edges on the bottom of the unit
(Example: Four (4) concrete masonry blocks).
FLUSH FACE LOUVERED
COMBUSTIBLE MATERIALS ALLOWED
Figure 4
Ifthereboxisinstalleddirectlyoncarpeting,tileorothercombustible
materialotherthanwoodooring,itshouldbeinstalledonametal
or wood panel extending the full width and depth of the unit.
At this point, you should have decided what components to include
inyourinstallation,andwherethereboxistobelocated.Ifthis
has not been done, stop and consult your dealer for assistance
with this planning.
Planning Your Installation
Accessory kits such as the FBB5 Blower kit, Trim kits, Mantels, plus
other Decorative Frame, Hood, and Door accessory kits may be
installedafterthereboxissecuredtotheframing.
Refer to the instructions provided with each of the optional accessory
kits for proper installation and operation.
Firebox Framing
Fireboxframingcanbebuiltbeforeorafterthereboxissetinplace.
Framing should be constructed to accommodate wall covering and
reboxfacingmaterial.Thereboxframingshouldbeconstructed
of 2 x 4 lumber or heavier. The framing headers may rest on the
topofthereboxstandoffs.RefertoFigure 5 forreboxframing
dimensions.
Note: On Peninsula models, a maximum weight of 250 lbs. is
recommended when construction materials are supported by the
top standoff spacers.
A
B
C
Framing - Peninsula
A
B
C
Framing - See-Through
Premium Vent-Free Firebox Framing Dimensions (in
inches)
"A" "B" "C"*
Model Framing
Height
Framing
Width
Framing
Depth
VFP36SB 41 1/2" 40" 23"*
VFP36PB 41 1/2" 39"** 23"*
Attention: Add height of base to "A" Dimension when elevat-
ingreboxifinstallingonanelevatedbase.
Framing dimension A incudes a three inch clearance for
standoffs on rebox.
*Dimension"C"assumesuseof1/2"wallboardushtoboth
front faces.
** Peninsula model framing width assumes use of 1/2" wall
boardushtotheendface.
Figure 5