Thereboxisdesignedtoacceptagaslineforanapprovedvent-
freegaslogset.Havethelineinstalledbyaqualiedserviceperson
in accordance with all building codes. Consult local building codes
to properly size the gas supply line leading to the connection of the
logsetburner.ThestateofMassachusettsrequiresthataexible
appliance connector cannot exceed three feet in length.
Gas access holes are provided through the side panel(s) of
the firebox. See Figure 10. Carefully remove the indented
knockout in the ceramic brick panel using a drill or utility knife.
See Figure 11.
Check gas type. Use only the gas type indicated on the gas log
set rating plate. If the gas listed on the plate is not your type of gas
supply, DO NOT INSTALL. Contact your dealer for proper model.
AlwaysuseanexternalregulatorforallLPreboxestoreducethe
supply tank pressure to a maximum of 14" w.c. This is in addition
totheregulatorttedtothelogset.
WARNING: CONNECTION DIRECTLY TO AN
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION.
InstallonlyaANSIZ21.11.2vent-freelogsetintothisrebox.
Figure 10
Figure 11
INSTALLING HOOD (continued)
GAS LINE CONNECTION
GAS LINE
ACCESS
HOLES
Extended Hoods
If your non-combustible facing material is over 1" in thickness and
willbeusedtonishthisrebox,extendedhoodsareavailablethat
will extend out 2" farther into the room. Extended hoods are not
available for the peninsula open ends. Contact your local dealer
for details.
Extended Hoods
VB4H36BL Standard Black (1 each)
VB4H36BR Polished Brass (1 each)
VB4H36SS Stainless Steel (1 each)
VB4H36HP Hammered Pewter (1 each)
Finishing
All joints (top, bottom and sides), where the wall or decorative
facingmaterialmeetsthereboxsurroundshouldbesealedwitha
non-combustible material.
Hearthextensionsarerequiredforthesereboxes.
Flush panels, louvers, and decorative louver panels are
interchangeable, and may be mixed and matched as desired (i.e.
Flush panel on bottom with louvered panel at top, or vice versa).