Specifications
18 EMPYRE PRO SERIES INSTALLATION AND OPERATION MANUAL
OPERATION
Larger diameter and irregular shaped logs are more
likely to cause wood to hang up or ‘bridge.’ Place the
larger logs on top.
3. Loadwoodintotherebox.
Ideal Log Size of Seasoned Wood
Diameter Length
+/- 2”(5 cm)
in cm in cm
Pro Series 200 6 15 26 66
Pro Series 400 7 18 34 86
Centrewoodintherebox.Thereshouldbeagapof
several inches between the wood and both the front
andbackoftherebox.Placingwoodupagainstthe
backofthereboxcanresultinunburnedwoodwhich
can cause logs to hang up.
4. Forthe mostefcientburnalwayskeepthe brick
hotbymaintainingwoodintherebox.
5. Do not cover the brick slots when placing wood into
therebox.
Daily Routine
Morning Loading:
Load wood into the unit as described above.
Late Afternoon Check:
Checktheunittoensurethereissufcientwoodtoburn
until the end of the day. Load just enough fuel to ensure
abedofburningcharcoalisinthereboxprior tothe
night loading.
Note: The rebox is hottestwhen the woodhas burnt
down to a bed of charcoal. When the primary chamber
has burnt down to this level, the rebox will dry out
and burn most of the accumulated creosote on the
walls. If the primary chamber is full all of the time, the
temperatureinthereboxstaysquitecoolandcreosote
may build up on the walls.
Night Loading:
Rakethecoalandashfromtheperimeteroftherebox
and especially from the back wall of the chamber where
ash tends to build up. With the ask rake, pull the ash
and charcoal away from the walls. The force of the fan
will blow the ash into the lower chamber on its own. If
this is done every day the ash should fall through the
slots easily.
Load wood into the unit as described above.
Cleaning Out Ash
Firebox and Secondary Burn Chamber
To clean ash outof the rebox,gently rakeit into the
secondary burn chamber through the openings in the
bottomoftherebox.
Ash in the secondary burn chamber should be cleaned
out weekly or as necessary, depending on fuel quality and
burn rate.
1. Dothiswhentherehasdieddownbeforereloading
furnace. Switch blower off.
2. Open ash clean out door.
3. Reach the ash rake to the back of the chamber and
pull ash forward into a steel container. Do not scrape
all of the ash out. It is recommended to leave 1-2”
(2.5-5.1cm)ofashcoveringtheooroftherebox.
4. Firmly close and latch ash clean out door.
5. Switch blower on.
Flues and Chimney
Check for y ash buildup in the ue area weekly.
1. Tocleanyashoutofueareaandchimney,switch
bloweroff,openrearaccessdoorandremoveue/
yashcleanoutcover.
2. Empty ash clean out tray into a steel container.
Sweepyashintoverticalues.
3. Sweeporvacuumouttheueareas.
4. To achieve the highest efciency in your furnace,
cleanallhorizontalandverticaluesregularlywith
ue cleaning tools. (see pg 8, item 21 Wire Brush
Flue Cleaning Rod.)
NOTE: Remove bafe (see pg 8, item 13) to gain
access to all ues. Caution: bafe may be hot.
Reinstall bafe after cleaning.
Pro Series 400: Removebafebyrstpullingforward
then slide to the right and up. When reinstalling,
bafemust beseatedoninside of sidestops(see
page 8, items 13 and 27).
Correct:
The rebox should be
loaded with wood of
proper length. This will
lengthen the burn time.
Incorrect:
The rebox loosely lled
with irregular pieces of
wood will decrease burn
time and may cause un-
necessary bridging.