Specifications
EMPYRE PRO SERIES INSTALLATION AND OPERATION MANUAL 19
OPERATION
5. When cleaning ues, also check for y ash build
upattheopening(locatedinreboxaboveloading
door)andcleanoutanyyashbuildup.
6. After cleaning, install back ue/y ash clean out
cover and tighten securely with wing nuts.
7. Switch blower on.
Disposal of Ash
Ashes should be placed in a metal container with a tight
ttinglid.Theclosedcontainerofashesshouldbeplaced
on a noncombustible oor or on the ground, wellaway
fromallcombustiblematerials,pendingnaldisposal.If
the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture
to form creosote. The creosote vapours condense on
therelativelycoolreboxwallsofaslowburningre.As
a result, creosote residue accumulates on the rebox
walls. When ignited this creosote makes an extremely
hot re. To reduce the amount of creosote, a small
intensereispreferrabletoalargesmolderingone.
Donotoverll.Allowfueltoburndown.
Fire Brick and Insulation
The secondary burn chamber of the Empyre Pro Series
high efciency furnace is lined with high temperature
insulation board. It is designed to sustain high furnace
temperatures and regular operation for many years. The
oorofthereboxislinedwithbrick.Toseesignsofwear
and cracking of the brick is normal.
Takethefollowingprecautions toprotectthe rebrick
and maintain optimal performance.
1. Do not carelessly throw heavy pieces of wood onto
the brick.
2. Gently rake ashes out of secondary burn chamber.
3. Donotdamagebrickwhilestirringthere.
4. Do not attempt to cool down hot bricks quickly.
5. Do not run furnace with pieces of brick missing.
6. Do not alter the brick and insulation layout. This
layout has been carefully engineered to achieve the
best performance.
Blower Draft Setting
The blower and apper unit ap opening settings
are pre-determined by the factory and must NOT
be altered. Altering these components could cause
damage to the furnace and void the warranty. To
replace any of these components you must contact
your Empyre Pro Series dealer.
NOTE: This is not a natural draft furnace. It is a
forcedairfurnacewheretheblowercontrolsthere.
Loading Door
The Empyre Pro Series includes special loading door
features for safety and ease of operation.
Loading Door Features:
• Adjustableandreplaceablehingesandlatch.
• A full length smoke curtain, which is linked to the
door. The smoke curtain stays in place for at least
half of the door travel.
• Smokeexitlid.Thesmokeexitlid isalsolinkedto
the loading door and opens when the loading door is
opened. The smoke exit lid allows smoke to escape
fromthereboxwhentheloadingdoorispartiallyor
fully opened.
To maintain optimal performance:
1.
Do not leave loading door open for extended periods of
time,especiallywhenthereisveryhot.
2. Do not force the loading door open beyond the stop.
3. Toavoidexcesscreosotebuildupinthereboxand
loading door, burn only seasoned wood.
Power Outages
TheEmpyreProSeriesfurnace,unlikeagasoroilred
appliance, does not stop generating heat when the power
is interrupted even though the blower automatically
shutsoff causing the re todie down.Asa result the
heattransferuidinthefurnacemayoverheatandboil
off through the vent. When power resumes be sure to
checktheuidlevel.