ABBREVIATED COMPONENT MAINTENANCE MANUAL
1458-A-1101 / 1458-A-1300
2. Procedure (TASK 23-15-30-400-801-A01)
A. Job Setup (Subtask 23-15-30-400-001-A01)
W
ARNING: BEFORE YOU USE A MATERIAL, REFER TO THE MANUFACTURERS’ MATE
RIAL
SAFETY DATA SHEETS. SOME MATERIALS CAN BE DANGEROUS.
C
AUTION: DO NOT USE MATERIALS THAT ARE NOT EQUIVALENT TO HONEYWELL
SPECIFIED MATERIALS. MATERIALS THAT ARE NOT EQUIVALENT CAN
CAUSE DAMAGE TO THE EQUIPMENT AND CAN MAKE THE WARRANTY NOT
APPLICABLE.
C
AUTION: DO NOT DROP OR HIT THE A350 SDU AND SCM DURING THESE PROCEDURES.
THE A350 SDU AND SCM CONTAINS AN ASSEMBLY THAT CAN BE DAMAGED
FROM INCORRECT USE.
C
AUTION: DO THESE PROCEDURES IN A CLEAN ENVIRONMENT TO PREVENT DAMAGE
TO MECHANICAL COMPONENTS.
(1) Obey the precautions.
B. Installation Data (Subtask 23-15-30-400-002-A01)
(1) Installation requirements are based on ARINC 781 specifications.
C. Unpacking and Inspecting Equipment (Subtask 23-15-30-400-003-A01)
(1) Unpack the equipment components from the shipping container. Visually inspect the units for
any shipping damage. Make sure that both the SDU and SCM are available.
SDU PN 1394-A-1100
SCM PN 1394-A-1300.
(2) If optional parts have been ordered, these items must be removed from the packaging and
visually inspected for any shipping damage.
D. Customer Acceptance Procedure (Subtask 23-15-30-400-004-A01)
(1) Make sure that the part number on the equipment received is correct as ordered.
(2) Check for physical damage that can occurred during shipping.
(3) Check the operational status of the SDU and SCM before installation on an aircraft by
performing the test procedures described in TESTING AND FAULT ISOLATION (PGBLK
23-15-30-1000).
E. Installation Procedure (Subtask 23-15-30-400-005-A01)
(1) General
(a) Only authorized technical personnel, trained in general aviation workmanship, that have a
basic understanding of SATCOM systems must proceed with the following procedure.
Before performing any installation procedures, read the safety advisories.
(2) SDU Installation
(a) Refer to Figure 11 (GRAPHIC 23-15-30-99B-811-A01).
(b) The A350 SDU uses ARINC 600 size 2 sh
ell receptacles located at the rear of the unit
and requires an ARINC 600 6 MCU tray
for installation.
(c) Refer to the interconnection diagrams to install the correct wiring for the services you
require. The interconnection and pinout drawings are also provided for information
purposes.
EFFECTIVITY
ALL
23-15-30
Page 64 of 70
5 Oct 2012
© Honeywell International Inc. Do not copy without express permission of Honeywell.