User's Manual

Table Of Contents
Page 2–29
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(f) Changing LES access codes using control processor software version 5.7 (or
later)
To change individual LES access codes in systems operating software version
5.7 up to version 7.0:
EEPROM LISTING:
MAGIC NUMBER :OK
EEPROM VERSION NUMBER 2001
FIRMWARE VERSION 1018
SERIAL NUMBER: 114
IGNORED FAULTS: 0
HARDWARE CONFIG: 0
NUMBER OF POWERUPS (index 0) 13
HOURS OF OPERATION (index 0) 49
MISCELLANEOUS PARAMETERS
HIT 'L' for MORE
MISCELLANEOUS PARAMETERS
HIT 'L' for MORE
HPA-ANTENNA CABLE LOSS: 2.5 dB
FORWARD ID: 000000
AORW LES ACCESS CODE: 1
TERRESTRIAL NETWORK ID: 0
HPA-CHANNEL CARD CABLE LOSS: 10.0 dB
MAX HPA GAIN: 65.0 dB
MIN ANTENNA GAIN: 11.0 dB
MAX EIRP: 53.5 dBm
MAX CHANNEL_CARD POWER: 0.0 dBm
NUMBER OF CHANNEL CARDS : 2
FRONT PANEL LEDS ENABLED: 1
RX ATTENUATION (LAND-ON-WINGS): 0.0 dB
MIN SECS BETWEEN CHAN CARD RESETS: 300
HIT 'L' for MORE
MAINTENANCE PORT INVERSE VIDEO: 0
MAINTENANCE PORT DEGREES SYMBOL: 0
TERMINAL CATEGORY: HW STRAPPED VALUE
AOR W VALID BEAMS: 4 5 6
AOR E VALID BEAMS: 5 6
POR VALID BEAMS: 4 5 6
IOR VALID BEAMS: 5 6
AORE LES ACCESS CODE: 1
POR LES ACCESS CODE: 1
IOR LES ACCESS CODE: 1
RECEIVER CALIBRATION (AERO): 11.0 dB
MAX HPA POWER: 18.0 dBw
HPA RESERVED POWER (AERO): 16.0 dBw
HIT 'L' for MORE
CHANNEL CARD STARTUP DELAY: 30 sec
RX32 ACTIVE: 1
DEFAULT LATITUDE: 45 D 0' 0.0" N
DEFAULT LONGITUDE: 75 D 0' 0.0" W
OBEY OXCO STATUS: YES
CC DEBUG PORT: NONE
COMBINED MODE BACKOFF ADJUSTMENT: 10.0 dB
CHECKSUM (stored at offset 462) 9695 OK
longest write cycle took 0 MSEC