User's Manual
Table Of Contents
- Introduction
- System Description
- 1. Purpose of Equipment
- 2. Equipment Covered
- 3. Equipment Description
- A. Applicable Documents
- B. Reference Documents
- C. Equipment Specifications
- D. Mechanical Description
- E. Electrical Description
- F. System Interface Descriptions
- G. User Interfaces
- (1) Stand-Alone Mode User Interfaces
- (2) Collins Cooperative Mode User Interfaces
- (3) Honeywell Combined Mode User Interfaces
- (4) Selective Mode User Interfaces
- (5) Multi-Channel Configurations
- (6) ISDN Circuit-Switched Data Interface
- (7) RS-232 Interface
- (8) Ethernet Data Interface
- (9) ISDN S/T Interface
- (10) Maintenance Port Interface
- H. Initiated-Self-Test
- I. Owner Requirements Table
- 4. Inmarsat System Overview
- 5. HSD Modes and Configuration Descriptions
- System Operation
- 1. Introduction
- 2. Activating HSD Transceivers
- 3. Configuring HSD Systems
- 4. Using the HSD System
- Installation
- 1. Introduction
- 2. Advisories
- 3. Pre-Installation Inspection
- 4. Unpacking and Inspecting Equipment
- 5. Cabling and Connector Requirements
- 6. ARINC 600 Trays and Connectors
- 7. Mechanical Installation
- 8. Electrical Installation
- 9. Outline/Installation and Interconnection/Contact Assignment Diagrams
- Test and Fault Isolation
- 1. Introduction
- 2. Operational and Diagnostic Testing
- 3. Troubleshooting and Fault Isolation
- 4. Adjustment/Alignment Procedures
- 5. Modification History
- Maintenance and Repair
- 1. General
- 2. Maintenance
- 3. Repair
- 4. Instructions for Continued Airworthiness, FAR 25.1529
- Appendix A: Inmarsat Satellite Beam Coverage
- Appendix B: Troubleshooting Checklist
- Appendix C: RJ-45 Cable Termination Details
- Appendix D: Installation Checklist
- Appendix E: Record of Accomplishment
- Appendix F: RF Splitter
Page 2–40
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(a) Loading Self-loading ORT Files
Self-loading ORT files have the HSD software load application embedded in the
file. Self-loading ORT files are executable. Opening the file executes the software
load application.
To load self-loading ORT configuration files onto an HSD or HSD-X unit:
1. Remove power from the system.
2. Connect a computer to the maintenance port of the HSD or HSD-X (Refer
to "Test and Fault Isolation" on page 4-1 for cabling and connection details.)
3. Turn on the computer.
4. Apply power to the unit.
5. Close all other applications running on the computer (especially programs
that use the serial COM port, e.g. HyperTerminal). The ORT load program
may not execute successfully if other programs are running.
6. Open the self-loading ORT configuration file.
The ORT Loader application window appears.
7. To load the self-loading, ORT configuration files, follow the directions as
indicated by the ORT Loader application.
The ORT Loader application loads the software to the unit connected to the
computer via the selected COM port. When the software load is complete,
the window closes.
(b) Loading Basic ORT Files
When loading a basic ORT file that does not have the self-loading application
embedded, load the file using the HSD serial loader, ADT_LOAD.exe (PN
1110-SW-1021).
Note: HSD ORT configuration files must be loaded into the HSD transceiver.
HSD-X ORT configuration files must be loaded into each of the
Multi-Channel HSD-X units installed on the system. The IP addresses are
automatically incremented.
To load basic ORT configuration files onto an HSD or HSD-X unit:
1. Remove power from the system.
2. Connect a computer to the maintenance port of the HSD or HSD-X (Refer
to "Test and Fault Isolation" on page 4-1 for cabling and connection details.)
3. Turn on the computer.
4. Apply power to the unit.