SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(a) Loading Self-loading ORT Files
Self-loading ORT files have the HSD software load application embedded in the
file. Self-loading ORT files are executable. Opening the file executes the software
load application.
To load self-loading ORT configuration files onto an HSD or HSD-X unit:
1. Remove power from the system.
2. Connect a computer to the maintenance port of the HSD or HSD-X (Refer
to "Test and Fault Isolation" on page 4-1 for cabling and connection details.)
3. Turn on the computer.
4. Apply power to the unit.
5. Close all other applications running on the computer (especially programs
that use the serial COM port, e.g. HyperTerminal). The ORT load program
may not execute successfully if other programs are running.
6. Open the self-loading ORT configuration file.
The ORT Loader application window appears.
7. To load the self-loading, ORT configuration files, follow the directions as
indicated by the ORT Loader application.
The ORT Loader application loads the software to the unit connected to the
computer via the selected COM port. When the software load is complete,
the window closes.
(b) Loading Basic ORT Files
When loading a basic ORT file that does not have the self-loading application
embedded, load the file using the HSD serial loader, ADT_LOAD.exe (PN
1110-SW-1021).
Note: HSD ORT configuration files must be loaded into the HSD transceiver.
HSD-X ORT configuration files must be loaded into each of the
Multi-Channel HSD-X units installed on the system. The IP addresses are
automatically incremented.
To load basic ORT configuration files onto an HSD or HSD-X unit:
1. Remove power from the system.
2. Connect a computer to the maintenance port of the HSD or HSD-X (Refer
to "Test and Fault Isolation" on page 4-1 for cabling and connection details.)
3. Turn on the computer.
4. Apply power to the unit.