User's Manual

Table Of Contents
Page 2–41
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
5. Close all other applications running on the computer (especially programs
that use the serial COM port, e.g. HyperTerminal). The load program may
not execute successfully if other programs are running.
6. Start the HSD Software Load program (ADT_LOAD.exe) to launch the load
program.
A DOS window opens displaying the “Load Target” menu; it shows a number
of load selection options.
7. From the “Which Target” menu:
•Type
15” to load the ORT file to an HSD unit.
•Type
16” to load the ORT file to an HSD-X unit.
8. Press Enter.
The load application prompts you to type in a filename.
9. Type the appropriate filename for the software being loaded to the unit, and
then press
Enter.
The application prompts you to select a COM port.
10. Select the COM port on your computer connected to the HSD.
11. Type the appropriate COM port (1 or 2—typically 1), and then
press Enter.
12. To start the load, press Enter.
Communication with the HSD transceiver is established. The following
screen appears. A percentage (%) progress indicator appears on the screen
showing load status. Once the load is complete, a confirmation message
briefly appears on the screen indicating that the file has been successfully
loaded. The DOS window then closes and the unit resets.
HSD/HST LOADER Vx.x -- Mon Mar 24 12:12:17 2003
which target ?
0 = control processor
1 = channel card #1
2 = channel card #2
3 = HPA application
4 = data i/o card
5 = HPA application with manual setup
6 = HPA application plus boot with manual setup
7 = HPA application plus boot
8 = channel card #1 boot code
9 = channel card #2 boot code
11 = channel card #1 pic code
12 = channel card #2 pic code
13 = HCM application
14 = HST ORT
15 – HSD ORT
16 – HSD-X ORT
?