User's Manual

Table Of Contents
Page 3–54
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
4. Connect the end coming from the antenna subsystem to the splitter input (S)
connector.
5. Connect the end going to TPC1 of the RFU to one of the output ports of the
splitter, one or two.
6. Run a new coax cable (length is installation specific) from the unused splitter
output port to BP-12 of the ARINC 600 connector of the HSD tray assembly.
(l) Cooperative Mode Connection Details
The tables in this section provide all top, middle, and bottom plug connection
details for Cooperative Mode installations.
Table 3–28. Receive Path Parts Requirements – Cooperative Mode
Item Manufacturer PN
EMS
SATCOM
PN
Description
RF Splitter ZAPD-2-TNC 32800004 Mini-Circuit, 2-way 0°, TNC,
Splitter
Receive Coax 432101 ECS, Coax Cable, 0.130 O.D.,
50
Ω, 17.5 dB/100 ft @ 1.5 GHz
Connector (@
Splitter)
CTS522 ECS, TNC, Straight Plug
Connector (@
BP12)
P522 ECS, ARINC 600, Size 5, Socket
Table 3–29. Cooperative Mode ARINC 600 Top Plug Connection Details
I/O
From
Top Plug
Signal Name To Description
I/O
1A to 1D Multi-Control IN and
BITE OUT
As per Collins
documentation
Multi-Control and BITE
I
2A BSU Top/Port BITE A SDU, MP7G ARINC Tx-HI BITE
From Top/Port BSU
I
2B BSU Top/Port BITE B SDU, MP7H ARINC Tx-LO BITE
From Top/Port BSU
I
2C BSU STBD BITE A Mechanically Steered
1
Antenna (MA):
Not
required
Other Antenna
2
(OA):
SDU, MP7J
ARINC Tx-HI BITE
From STBD BSU
I
2D BSU STBD BITE B MA: Not required
OA
: SDU, MP7K
ARINC Tx-LO BITE
From STBD BSU
O
2E OUT SDU Crosstalk
A
SDU, MP12A ARINC 429
O
2F OUT SDU Crosstalk
B
SDU, MP12B ARINC 429