User's Manual

Table Of Contents
Page 4–68
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
(b) Installation Check – Multi-Channel
Conduct the following installation check to confirm proper Multi-Channel
installation and configuration before performing the operational verification tests.
Before beginning the system checks, connect to the HSD-128 Maintenance Port
and open the HSD Maintenance Utility Program using the password MAINT.
1. Check the Forward ID in all units.
•In Menu 4, press Q.
2. Check the System Config and I/O strapping is correctly installed for all units.
Activate Report 28: Press the equal sign “=”, type 28, press Enter, and
then press Esc to activate the report.
3. Check the cable loss values are in the required range.
4. Check that LES Access Codes are configured correctly in all units.
•In Menu 3, press O (until the LES access codes are displayed).
5. Check that the HSD-X “slaves” are recognized by the system.
Activate Report 78: Press the equal sign “=”, type 78, press Enter, and
then press Esc to activate the report
. All installed HSD-X units should be
listed on screen as shown in the 4-channel system example below.
MENU 18 FIRMWARE Vx.x
X HSD-X slave console mode B HSD-X slave cable loss
L list HSD-X slave cable loss V get HSD-X firmware version
<CTRL> N next menu <CTRL> O previous menu = select reports
TERMINAL: HSD-X NETWORK MODE
which slave (1 thru 2 -- 0=none) ? 1
Slave #1 console mode. Press ~ to exit.
MENU 1 FIRMWARE Vx.x
X override forward id L test LEDs
Y explain hpa error status S set hcm attenuator
R hcm RF threshold
<CTRL> N next menu <CTRL> O previous menu = select reports
TERMINAL: HSD-X NETWORK MODE
ID=XXXXXX config=11111000 DUART1=11101111 DUART2=10001111 DUART3=11111111
DATA I/O CONFIG=00001010