User's Manual

Table Of Contents
Page 4–73
18 September 2007
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
eNfusion™ HSD-128 High-speed Data Terminal
This completes the first load of the Channel Card software selected in step 10.
14. For HSD transceivers with two channel cards, repeat all required software loads
to both channel cards.
15. Repeat steps 7 through 13 for all other required software loads of Channel Card
Software files as specified in the applicable software service bulletin.
16. When all Channel Card Software is loaded, reset or cycle the power on the HSD
transceiver.
17. If no other software loads are required, proceed to "Verifying Software Loads" on
page 4-78.
18. In the event that the load fails, restart the load from the beginning of the Loading
Channel Card Software procedure. If after two attempts the load still does not
complete successfully, assume that the software disks or files may have been
corrupted or the software is incompatible with the hardware configuration. Contact
EMS SATCOM product support for assistance.
(2) Loading Control Processor Software
CAUTION: When loading software to the units in installation environments that
include an SDU, disable the SDU (Power off or remove the sdu from the
arinc tray) before beginning the software load procedure.
HSD/HST LOADER Vx.x -- Mon Mar 24 12:12:17 2003
which target ?
0 = control processor
1 = channel card #1
2 = channel card #2
3 = HPA application
4 = data i/o card
5 = HPA application with manual setup
6 = HPA application plus boot with manual setup
7 = HPA application plus boot
8 = channel card #1 boot code
9 = channel card #2 boot code
11 = channel card #1 pic code
12 = channel card #2 pic code
13 = HCM application
14 = HST ORT
15 = HSD ORT
16 = HSD-X ORT
?1
File name, which contains the firmware image? applxx.hex
This download will require one of the PC's COM ports. (1, 2, etc) [1] ?
1
Connect COM1 of this PC to the maintenance port of the data terminal.
Hit <ESC> to abort, or <Enter> to proceed
Establishing communication to the data terminal -- DO NOT CYCLE THE POWER !!
Hit ESC to abort.
DATA TERMINAL APPARENTLY READY TO ACCEPT PROGRAM
switching to 57.6 kbaud
loading applxx.hex
1% 5% 10%